The combination use of the UF-1000i automated urine analyzer and DiaSys urinary sediment quantitative analysis workstation in detecting urinary cast

Tingting Zeng

Open publisher page 0 citations

Abstract

Objective To investigate the combination use of the UF-1000i automated urine analyzer(UF-1000i) and DiaSys urinary sediment quantitative analysis workstation(R/S500) in detecting urinary cast.Methods 3492 samples were tested for urine cast by both UF-1000i and R/S500,and results of them were compared.Results 969(27.75%) samples were positive of cast tested by UF-1000i in 3492 samples.Meanwhile,157(4.50%) samples were positive of cast tested by R/S500.Sensitivity,specificity,false positive rate,false negative rate,positive predictive value and negative predictive value of UF-1000i in detection of cast was 91.08%,75.23%,24.77%,8.92%,14.76% and 99.45%,respectively.The difference between positive results of UF-1000i and R/S500 was statistically significant(P0.01).Conclusion UF-1000i automated urine analyzer can rapidly screen urine sediment,but had a higher false positive rate of cast,and there are some false negative samples.UF-1000i automated urine analyzer must be combined with the DiaSys(R/S500) urinary sediment quantitative analysis workstation to effectively reduce the false positive and false negative results and to prevent false and missing detection,and can also make the urine sediment analysis truly achieve standardization,automation.

About this research paper

What this paper is about

Objective To investigate the combination use of the UF-1000i automated urine analyzer(UF-1000i) and DiaSys urinary sediment quantitative analysis workstation(R/S500) in detecting urinary cast.Methods 3492 samples were tested for urine cast by both UF-1000i and R/S500,and results of them were compared.Results 969(27.75%) samples were positive of cast tested by UF-1000i in 3492 samples.Meanwhile,157(4.50%) samples were positive of cast tested by R/S500.Sensitivity,specificity,false positive rate,false negative rate,positive predictive value and negative predictive value of UF-1000i in detection of cast was 91.08%,75.23%,24.77%,8.92%,14.76% and 99.45%,respectively.The difference between positive results of UF-1000i and R/S500 was statistically significant(P0.01).Conclusion UF-1000i automated urine analyzer can rapidly screen urine sediment,but had a higher false positive rate of cast,and there are some false negative samples.UF-1000i automated urine analyzer must be combined with the DiaSys(R/S500) urinary sediment quantitative analysis workstation to effectively reduce the false positive and false negative results and to prevent false and missing detection,and can also make the urine sediment analysis truly achieve standardization,automation.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To investigate the combination use of the UF-1000i automated urine analyzer(UF-1000i) and DiaSys urinary sediment quantitative analysis workstation(R/S500) in detecting urinary cast.Methods 3492 samples were tested for urine cast by both UF-1000i and R/S500,and results of them were compared.Results 969(27.75%) samples were positive of cast tested by UF-1000i in 3492 samples.Meanwhile,157(4.50%) samples were positive of cast tested by R/S500.Sensitivity,specificity,false positive rate,false negative rate,positive predictive value and negative predictive value of UF-1000i in detection of cast was 91.08%,75.23%,24.77%,8.92%,14.76% and 99.45%,respectively.The difference between positive results of UF-1000i and R/S500 was statistically significant(P0.01).Conclusion UF-1000i automated urine analyzer can rapidly screen urine sediment,but had a higher false positive rate of cast,and there are some false negative samples.UF-1000i automated urine analyzer must be combined with the DiaSys(R/S500) urinary sediment quantitative analysis workstation to effectively reduce the false positive and false negative results and to prevent false and missing detection,and can also make the urine sediment analysis truly achieve standardization,automation.

Key concepts: Urinary sediment, Urine, Medicine, Urinary system, Predictive value, False positive rate, Spectrum analyzer, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
The combination use of the UF-1000i automated urine analyzer and DiaSys urinary sediment quantitative analysis workstation in detecting urinary cast — Research Paper | ScholarLens