2013•China Journal of Chinese Materia MedicaRequires access

Simultaneous determination of eight active components in Chrysanthemum indicum by HPLC

Sheng Dai, Ming Zhang, Wenming Cheng, Xun Zhang, Qunlin Zhang, Jun Li

Open publisher page 3 citations

Abstract

This study is aimed to establish a high-performance liquid chromatography (HPLC) method for simultaneous determination of chlorogenic acid, caffeic acid, 1,3-dicaffeoylquinic acid, 3,5-dicaffeoylquinic acid, luteolin-7-O-beta-D-glucoside, 3,4-dicaffeoylquinic acid, linarin and luteolin in Chrysanthemum indicum. The separation was carried out on a Shim pack VP-ODS (4.6 mm x 250 mm, 5 microm) column eluting with mobile phases of methanol (A) and water containing 0.3% phosphoric acid (B) in gradient mode (0-9 min, 85% -80% B; 9-12 min, 80% -70% B; 12-15 min, 70% -65% B; 15-20 min, 65% -60% B; 20-23 min, 60% -55% B; 23-29 min, 55% -54.4% B; 29-32 min, 54.4% -45% B; 32-37 min, 45% -5% B; 37-45 min, 5% -85% B) at the flow rate of 1.0 mL x min(-1). The column temperature was 35 degrees C and the detection wavelength was set at 326 nm. The good separation of chlorogenic acid, caffeic acid, 1,3-dicaffeoylquinic acid, 3,5-dicaffeoylquinic acid, luteolin-7-O-beta-D-glucoside, 3,4-dicaffeoylquinic acid, linarin and luteolin was achieved within 40 min. Calibration curves of the eight effective components showed good linear relationship (r > 0.999 5, n = 7). The average recoveries were within 97.03%-102.3% (RSD < 2.0%, n = 6). The method is simple, accurate and repeatable and can be used for the quality control of Ch. indicum.

About this research paper

What this paper is about

This study is aimed to establish a high-performance liquid chromatography (HPLC) method for simultaneous determination of chlorogenic acid, caffeic acid, 1,3-dicaffeoylquinic acid, 3,5-dicaffeoylquinic acid, luteolin-7-O-beta-D-glucoside, 3,4-dicaffeoylquinic acid, linarin and luteolin in Chrysanthemum indicum. The separation was carried out on a Shim pack VP-ODS (4.6 mm x 250 mm, 5 microm) column eluting with mobile phases of methanol (A) and water containing 0.3% phosphoric acid (B) in gradient mode (0-9 min, 85% -80% B; 9-12 min, 80% -70% B; 12-15 min, 70% -65% B; 15-20 min, 65% -60% B; 20-23 min, 60% -55% B; 23-29 min, 55% -54.4% B; 29-32 min, 54.4% -45% B; 32-37 min, 45% -5% B; 37-45 min, 5% -85% B) at the flow rate of 1.0 mL x min(-1). The column temperature was 35 degrees C and the detection wavelength was set at 326 nm. The good separation of chlorogenic acid, caffeic acid, 1,3-dicaffeoylquinic acid, 3,5-dicaffeoylquinic acid, luteolin-7-O-beta-D-glucoside, 3,4-dicaffeoylquinic acid, linarin and luteolin was achieved within 40 min. Calibration curves of the eight effective components showed good linear relationship (r > 0.999 5, n = 7). The average recoveries were within 97.03%-102.3% (RSD < 2.0%, n = 6). The method is simple, accurate and repeatable and can be used for the quality control of Ch. indicum.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study is aimed to establish a high-performance liquid chromatography (HPLC) method for simultaneous determination of chlorogenic acid, caffeic acid, 1,3-dicaffeoylquinic acid, 3,5-dicaffeoylquinic acid, luteolin-7-O-beta-D-glucoside, 3,4-dicaffeoylquinic acid, linarin and luteolin in Chrysanthemum indicum. The separation was carried out on a Shim pack VP-ODS (4.6 mm x 250 mm, 5 microm) column eluting with mobile phases of methanol (A) and water containing 0.3% phosphoric acid (B) in gradient mode (0-9 min, 85% -80% B; 9-12 min, 80% -70% B; 12-15 min, 70% -65% B; 15-20 min, 65% -60% B; 20-23 min, 60% -55% B; 23-29 min, 55% -54.4% B; 29-32 min, 54.4% -45% B; 32-37 min, 45% -5% B; 37-45 min, 5% -85% B) at the flow rate of 1.0 mL x min(-1). The column temperature was 35 degrees C and the detection wavelength was set at 326 nm. The good separation of chlorogenic acid, caffeic acid, 1,3-dicaffeoylquinic acid, 3,5-dicaffeoylquinic acid, luteolin-7-O-beta-D-glucoside, 3,4-dicaffeoylquinic acid, linarin and luteolin was achieved within 40 min. Calibration curves of the eight effective components showed good linear relationship (r > 0.999 5, n = 7). The average recoveries were within 97.03%-102.3% (RSD < 2.0%, n = 6). The method is simple, accurate and repeatable and can be used for the quality control of Ch. indicum.

Key concepts: Chlorogenic acid, Chemistry, Chromatography, Luteolin, Caffeic acid, Phosphoric acid, High-performance liquid chromatography, Flavonoid

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous determination of eight active components in Chrysanthemum indicum by HPLC — Research Paper | ScholarLens