THE COMPARSION OF CUTTING BALLOON ANGIOGRAPHY AND CONVENTIONAL TRANSLUMINAL CORONARY ANGIOPLASTY IN TREATMENT OF IN-STENT RESTENOSIS
Qunying Xi
Abstract
Qunying Xi
Abstract
Objective To determine if the cutting balloon angioplasty has advantages over conventional balloon percutaneous transluminal coronary angioplasty (PTCA) in treatment of in-stent restenosis (ISR). Methods A total of 266 lesions treated for ISR were divided into two groups according to the treatment strategy: conventional balloon PTCA and cutting balloon angioplasty. Angiogram obtained during the procedure and 6 month after the two interventions, and quantitative angiograpic analysis was performed. Results ①Immediately after intervention, the maxium luminal diameter(MLD) in cutting balloon angioplasty group was similar to the one achieved of conventional balloon angioplasty[(2.51±0.65) vs (2.53±0.65) mm, P0.05]. ②At six-month follow-up, the MLD has no significant change between the conventional balloon PTCA group and the cutting balloon angioplasty group [(1.75±0.83) vs (1.96±0.74) mm, P0.05]. ③The cutting balloon angioplasty group has a lower late lumen loss(P0.05). Conclusion We conclude that cutting balloon angioplasty did not increase the MLD immediately after intervention and at 6-month follow-up as compared with conventional balloon angioplasty in the treatment of in-stent restenosis, but with a less late lumen loss.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To determine if the cutting balloon angioplasty has advantages over conventional balloon percutaneous transluminal coronary angioplasty (PTCA) in treatment of in-stent restenosis (ISR). Methods A total of 266 lesions treated for ISR were divided into two groups according to the treatment strategy: conventional balloon PTCA and cutting balloon angioplasty. Angiogram obtained during the procedure and 6 month after the two interventions, and quantitative angiograpic analysis was performed. Results ①Immediately after intervention, the maxium luminal diameter(MLD) in cutting balloon angioplasty group was similar to the one achieved of conventional balloon angioplasty[(2.51±0.65) vs (2.53±0.65) mm, P0.05]. ②At six-month follow-up, the MLD has no significant change between the conventional balloon PTCA group and the cutting balloon angioplasty group [(1.75±0.83) vs (1.96±0.74) mm, P0.05]. ③The cutting balloon angioplasty group has a lower late lumen loss(P0.05). Conclusion We conclude that cutting balloon angioplasty did not increase the MLD immediately after intervention and at 6-month follow-up as compared with conventional balloon angioplasty in the treatment of in-stent restenosis, but with a less late lumen loss.
Key concepts: Balloon, Angioplasty, Restenosis, Medicine, Cutting balloon, Lumen (anatomy), Stent, Angiography