2010•Proceedings of the CSEERequires access

Applied Research on the Serial Distribution Mode of Heating System

Zhi-yuan Zhao

Open publisher page 1 citations

Abstract

It was proposed that the system for heating was operated in series distribution after the non-throttle conditions to reduce the throttle loss and improve the power generation through analyzing the combined characteristic of the cogeneration heating and power system,for the current situation that the heating system was used in parallel distribution in the most of power plant in China.At the same time,several different distribution mode models were also proposed,and then compared quantively and analyzed.It can be known that the extraction pressure for heating of the first stage units is decreased and that of the second stage units is increasing when the heating system are operating in series,but,totally,the extraction pressure for heating of units which operats in series is lower than the extraction pressure for heating of units which operats in parallel;in order to better use the extraction pressure for heating reduced by the first stage unites which operates in series,the thermal system heater area should be increased or the enhanced heat transfer tube should be used,so,they can increase the heat transfer performance to decrease the extraction pressure for heating of the second stage units in series,which increased in originally;so that the generating capacity increases more and the energy cascade utilization is achieved.

About this research paper

What this paper is about

It was proposed that the system for heating was operated in series distribution after the non-throttle conditions to reduce the throttle loss and improve the power generation through analyzing the combined characteristic of the cogeneration heating and power system,for the current situation that the heating system was used in parallel distribution in the most of power plant in China.At the same time,several different distribution mode models were also proposed,and then compared quantively and analyzed.It can be known that the extraction pressure for heating of the first stage units is decreased and that of the second stage units is increasing when the heating system are operating in series,but,totally,the extraction pressure for heating of units which operats in series is lower than the extraction pressure for heating of units which operats in parallel;in order to better use the extraction pressure for heating reduced by the first stage unites which operates in series,the thermal system heater area should be increased or the enhanced heat transfer tube should be used,so,they can increase the heat transfer performance to decrease the extraction pressure for heating of the second stage units in series,which increased in originally;so that the generating capacity increases more and the energy cascade utilization is achieved.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

It was proposed that the system for heating was operated in series distribution after the non-throttle conditions to reduce the throttle loss and improve the power generation through analyzing the combined characteristic of the cogeneration heating and power system,for the current situation that the heating system was used in parallel distribution in the most of power plant in China.At the same time,several different distribution mode models were also proposed,and then compared quantively and analyzed.It can be known that the extraction pressure for heating of the first stage units is decreased and that of the second stage units is increasing when the heating system are operating in series,but,totally,the extraction pressure for heating of units which operats in series is lower than the extraction pressure for heating of units which operats in parallel;in order to better use the extraction pressure for heating reduced by the first stage unites which operates in series,the thermal system heater area should be increased or the enhanced heat transfer tube should be used,so,they can increase the heat transfer performance to decrease the extraction pressure for heating of the second stage units in series,which increased in originally;so that the generating capacity increases more and the energy cascade utilization is achieved.

Key concepts: Throttle, Extraction (chemistry), Cogeneration, Cascade, Power (physics), Heat transfer, Series (stratigraphy), Heating system

Related papers

Back to paper searchBrowse research topicsOriginal source
Applied Research on the Serial Distribution Mode of Heating System — Research Paper | ScholarLens