[Determination of melamine in milk and milk powder by high performance capillary electrophoresis].
Qinxiong Rao, Jing Tong, Ping Guo, Haiyan Li, Xing‐Fang Li, Shuangyang Ding
Abstract
Qinxiong Rao, Jing Tong, Ping Guo, Haiyan Li, Xing‐Fang Li, Shuangyang Ding
Abstract
A high performance capillary electrophoresis (HPCE) method has been established for the separation of melamine in milk and milk powder. The separation was carried out on a fused-silica uncoated capillary column (58.5 cm x 75 microm). The sample was injected by hydrodynamic injection (3.5 kPa (35 mbar) x 8 s) at a temperature of 25 degrees C. The analysis was completed in about 6 min in 40 mmol/L Na2HPO4-20 mmol/L citric acid buffer (pH 2.6) at 25 kV of separation voltage and 232 nm of detection wavelength. The linear range of melamine was 1 - 100 mg/kg, and the correlation coefficient was higher than 0. 997. The limits of quantification (LOQs) in milk and milk powder were 0.5 mg/kg and 1.0 mg/kg, respectively. The average recoveries were in the range of 72.2% -97.3% in the spiked range of the concentration of LOQs and 50 mg/kg, and the relative standard deviations were between 2.1% and 3.9%.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A high performance capillary electrophoresis (HPCE) method has been established for the separation of melamine in milk and milk powder. The separation was carried out on a fused-silica uncoated capillary column (58.5 cm x 75 microm). The sample was injected by hydrodynamic injection (3.5 kPa (35 mbar) x 8 s) at a temperature of 25 degrees C. The analysis was completed in about 6 min in 40 mmol/L Na2HPO4-20 mmol/L citric acid buffer (pH 2.6) at 25 kV of separation voltage and 232 nm of detection wavelength. The linear range of melamine was 1 - 100 mg/kg, and the correlation coefficient was higher than 0. 997. The limits of quantification (LOQs) in milk and milk powder were 0.5 mg/kg and 1.0 mg/kg, respectively. The average recoveries were in the range of 72.2% -97.3% in the spiked range of the concentration of LOQs and 50 mg/kg, and the relative standard deviations were between 2.1% and 3.9%.
Key concepts: Chemistry, Melamine, Capillary electrophoresis, Chromatography, Analytical Chemistry (journal), Citric acid, Correlation coefficient, Capillary action