2014The World of Building MaterialsRequires access

Experimental Analysis of Concrete Members Reinforced by Paste Method in the Fire

FU Su-jua

Open publisher page 0 citations

Abstract

The fire resistance rating of concrete members coated with different thickness of fire-resistant coating was analyzed by experiment in the fire.Studies showed that the impact of CFRP and steel on the temperature field of the specimens was the same,the fireproof effect of thick-layer fire-resistant coating for steel structure was obvious,the thickness of the fire-resistant coating and the fire performance are not proportional.It identified that the best values of the fire retardant coating thickness is 40mm.

About this research paper

What this paper is about

The fire resistance rating of concrete members coated with different thickness of fire-resistant coating was analyzed by experiment in the fire.Studies showed that the impact of CFRP and steel on the temperature field of the specimens was the same,the fireproof effect of thick-layer fire-resistant coating for steel structure was obvious,the thickness of the fire-resistant coating and the fire performance are not proportional.It identified that the best values of the fire retardant coating thickness is 40mm.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The fire resistance rating of concrete members coated with different thickness of fire-resistant coating was analyzed by experiment in the fire.Studies showed that the impact of CFRP and steel on the temperature field of the specimens was the same,the fireproof effect of thick-layer fire-resistant coating for steel structure was obvious,the thickness of the fire-resistant coating and the fire performance are not proportional.It identified that the best values of the fire retardant coating thickness is 40mm.

Key concepts: Coating, Materials science, Fire resistance, Composite material, Fire retardant, Fire protection, Fire performance, Layer (electronics)