Residual Dynamics of Rotenone in Greengrocery by Solid-phase Extraction-High Performance Liquid Chromatography-UV Detection
Suning Wang
Abstract
Suning Wang
Abstract
[Aims] An analytical method for residual dynamics of rotenone in greengrocery by solid-phase extraction(SPE) and high performance liquid chromatography(HPLC)-UV detection was described.[Methods] The sample was extracted by acetonitrile,salted out by adding sodium chloride,and cleaned with Florisil SPE using n-hexane-ethyl ether(3∶7,by vol) as eluents to provide adequate recovery of rotenone.The detection of rotenone was then carried out by HPLC-UV at 290 nm with acetonitrile and water(6∶4,by vol) as the mobile phase.[Results] The method was accurate,specific and sensitive,and had good linear correlations at the concentration range of 0.05-10 mg/L.The average recoveries and the relative standard deviation ranged from 85.9-86.3% at concentration range of 0.5-5 mg/kg.The limits of detection(LOD) of rotenone were 0.05 mg/kg.When greengrocery was treated with rotenone 2.5% EC at recommended dose and 2 times recommended dose,the original residues rotenone in greengrocery were 6.26 and 18.34 mg/kg.[Conclusions] The compound degraded fast in the field.The half-life of rotenone in greengrocery was 11.2 and 11.1 h.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
[Aims] An analytical method for residual dynamics of rotenone in greengrocery by solid-phase extraction(SPE) and high performance liquid chromatography(HPLC)-UV detection was described.[Methods] The sample was extracted by acetonitrile,salted out by adding sodium chloride,and cleaned with Florisil SPE using n-hexane-ethyl ether(3∶7,by vol) as eluents to provide adequate recovery of rotenone.The detection of rotenone was then carried out by HPLC-UV at 290 nm with acetonitrile and water(6∶4,by vol) as the mobile phase.[Results] The method was accurate,specific and sensitive,and had good linear correlations at the concentration range of 0.05-10 mg/L.The average recoveries and the relative standard deviation ranged from 85.9-86.3% at concentration range of 0.5-5 mg/kg.The limits of detection(LOD) of rotenone were 0.05 mg/kg.When greengrocery was treated with rotenone 2.5% EC at recommended dose and 2 times recommended dose,the original residues rotenone in greengrocery were 6.26 and 18.34 mg/kg.[Conclusions] The compound degraded fast in the field.The half-life of rotenone in greengrocery was 11.2 and 11.1 h.
Key concepts: Rotenone, Chemistry, Chromatography, Detection limit, High-performance liquid chromatography, Solid phase extraction, Extraction (chemistry), Acetonitrile