2010•Industrial Water & WastewaterRequires access

Pretreatment of wastewater from flax production by Fenton reagent

SI Hong-liang

Open publisher page 0 citations

Abstract

Fenton reagent was used to pretreat wastewater from flax production.The influences of pH value,reaction time,H2O2 dosage and FeSO4.7H2O dosage on CODCr removal were investigated.The results of the test showed that: under the condition that,the pH value was 4.5,the reaction time was 60 min,the dosage of H2O2 and FeSO4.7H2O were 5 mL / L and 1 500 mg / L respectively,the H2O2 was added to the reactor batch by batch continuously,the removal rate of CODCr reached 45%,the m(BOD5) / m(CODCr) of the wastewater increased from 0.21 to 0.53,and no SS was detected in the effluent water,which provided favorable conditions for the subsequent biochemical treatment.

About this research paper

What this paper is about

Fenton reagent was used to pretreat wastewater from flax production.The influences of pH value,reaction time,H2O2 dosage and FeSO4.7H2O dosage on CODCr removal were investigated.The results of the test showed that: under the condition that,the pH value was 4.5,the reaction time was 60 min,the dosage of H2O2 and FeSO4.7H2O were 5 mL / L and 1 500 mg / L respectively,the H2O2 was added to the reactor batch by batch continuously,the removal rate of CODCr reached 45%,the m(BOD5) / m(CODCr) of the wastewater increased from 0.21 to 0.53,and no SS was detected in the effluent water,which provided favorable conditions for the subsequent biochemical treatment.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Fenton reagent was used to pretreat wastewater from flax production.The influences of pH value,reaction time,H2O2 dosage and FeSO4.7H2O dosage on CODCr removal were investigated.The results of the test showed that: under the condition that,the pH value was 4.5,the reaction time was 60 min,the dosage of H2O2 and FeSO4.7H2O were 5 mL / L and 1 500 mg / L respectively,the H2O2 was added to the reactor batch by batch continuously,the removal rate of CODCr reached 45%,the m(BOD5) / m(CODCr) of the wastewater increased from 0.21 to 0.53,and no SS was detected in the effluent water,which provided favorable conditions for the subsequent biochemical treatment.

Key concepts: Effluent, Wastewater, Reagent, Chemistry, Pulp and paper industry, Sewage treatment, Chromatography, Waste management

Related papers

Back to paper searchBrowse research topicsOriginal source
Pretreatment of wastewater from flax production by Fenton reagent — Research Paper | ScholarLens