Studied on the influence of chloride ion to nitrate determination when using ion chromatography to analyze low amount of nitrate in the hydrochloric acid solution.By adding the silver oxide,the chloride ion was removed and the pH of hydrochloric acid solution was adjusted to be neutral.Then the sample was injected in to the ion chromatography to determine the concentration of nitrate.The RSD of this method is 0.05%~1.5%(n3),and the average yield is 99.3%.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Studied on the influence of chloride ion to nitrate determination when using ion chromatography to analyze low amount of nitrate in the hydrochloric acid solution.By adding the silver oxide,the chloride ion was removed and the pH of hydrochloric acid solution was adjusted to be neutral.Then the sample was injected in to the ion chromatography to determine the concentration of nitrate.The RSD of this method is 0.05%~1.5%(n3),and the average yield is 99.3%.