2007•Metallurgical AnalysisRequires access

Determination of micro chromium,copper,magnesium and iron in silicon aluminum alloy by flame atomic absorption spectrometry

Feng Xue-zhu

Open publisher page 3 citations

Abstract

A new method for the determination of micro Cr,Cu,Mg and Fe by flame atomic absorption spectrometry(FAAS) was developed.Sample was dissolved in a mixture of NaOH,H2O and HNO3.The SrCl2 solution was used as releasing agent.The standard addition method was selected to eliminate the physiochemical influence and disturbance from matrix effect and sample injection.In the determination of 3 μg/mL Cr and Cu,10 μg/mL Mg and 4 μg/mL Fe,there is no interference from 100 μg/mL Na+ and K+,80 μg/mL Ca2+,50 μg/mL Zn2+,Mn2+,Pb2+ and Cd2+,30 μg/mL Ni2+ and Co2+.Cr,Cu,Mg,Fe at 100 μg/mL do not interfere each other as well.The method has been used to the determination of Cr,Cu,Mg and Fe in silicon aluminum alloy with the recovery of 96.5%-102.4% and the relative standard deviation of 0.73%-2.97%.The results are consistent with those of spectrophotometry.

About this research paper

What this paper is about

A new method for the determination of micro Cr,Cu,Mg and Fe by flame atomic absorption spectrometry(FAAS) was developed.Sample was dissolved in a mixture of NaOH,H2O and HNO3.The SrCl2 solution was used as releasing agent.The standard addition method was selected to eliminate the physiochemical influence and disturbance from matrix effect and sample injection.In the determination of 3 μg/mL Cr and Cu,10 μg/mL Mg and 4 μg/mL Fe,there is no interference from 100 μg/mL Na+ and K+,80 μg/mL Ca2+,50 μg/mL Zn2+,Mn2+,Pb2+ and Cd2+,30 μg/mL Ni2+ and Co2+.Cr,Cu,Mg,Fe at 100 μg/mL do not interfere each other as well.The method has been used to the determination of Cr,Cu,Mg and Fe in silicon aluminum alloy with the recovery of 96.5%-102.4% and the relative standard deviation of 0.73%-2.97%.The results are consistent with those of spectrophotometry.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new method for the determination of micro Cr,Cu,Mg and Fe by flame atomic absorption spectrometry(FAAS) was developed.Sample was dissolved in a mixture of NaOH,H2O and HNO3.The SrCl2 solution was used as releasing agent.The standard addition method was selected to eliminate the physiochemical influence and disturbance from matrix effect and sample injection.In the determination of 3 μg/mL Cr and Cu,10 μg/mL Mg and 4 μg/mL Fe,there is no interference from 100 μg/mL Na+ and K+,80 μg/mL Ca2+,50 μg/mL Zn2+,Mn2+,Pb2+ and Cd2+,30 μg/mL Ni2+ and Co2+.Cr,Cu,Mg,Fe at 100 μg/mL do not interfere each other as well.The method has been used to the determination of Cr,Cu,Mg and Fe in silicon aluminum alloy with the recovery of 96.5%-102.4% and the relative standard deviation of 0.73%-2.97%.The results are consistent with those of spectrophotometry.

Key concepts: Chromium, Atomic absorption spectroscopy, Copper, Magnesium, Analytical Chemistry (journal), Chemistry, Alloy, Silicon

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of micro chromium,copper,magnesium and iron in silicon aluminum alloy by flame atomic absorption spectrometry — Research Paper | ScholarLens