2006Unpublished venueRequires access

Determination of content of aluminum in silicon-aluminum residue with spectrophotometry

Liu Jian-hua

Open publisher page 0 citations

Abstract

Using chrome azurol S as a coloured system,the content of aluminum in silicon-aluminum residue was determined with spectrophotometry,and the effects of surfactants,pH values of solution,color reagent and their volumes on absorptions were investigated.The experiment results showed as follows:on the condition of the presence of CTMAB,the maximum absorption of aluminum was at 558 nm with CAS as a indicating color reagent in the buffer solution of HAc-NaAc(pH=5.0).The Beer's law was well obeyed in the range of 0~15/L for aluminum,and the linear regression eqution was Y=0.049 1ρ- 0.032 9 and the correlation coefficient was 0.999 6.The method had been applied to the determination of content of aluminum in silicon-aluminum residue,the relative standard deviations were 1.31%~3.35%,and the recoveries were 98.86%~101.04%.

About this research paper

What this paper is about

Using chrome azurol S as a coloured system,the content of aluminum in silicon-aluminum residue was determined with spectrophotometry,and the effects of surfactants,pH values of solution,color reagent and their volumes on absorptions were investigated.The experiment results showed as follows:on the condition of the presence of CTMAB,the maximum absorption of aluminum was at 558 nm with CAS as a indicating color reagent in the buffer solution of HAc-NaAc(pH=5.0).The Beer's law was well obeyed in the range of 0~15/L for aluminum,and the linear regression eqution was Y=0.049 1ρ- 0.032 9 and the correlation coefficient was 0.999 6.The method had been applied to the determination of content of aluminum in silicon-aluminum residue,the relative standard deviations were 1.31%~3.35%,and the recoveries were 98.86%~101.04%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Using chrome azurol S as a coloured system,the content of aluminum in silicon-aluminum residue was determined with spectrophotometry,and the effects of surfactants,pH values of solution,color reagent and their volumes on absorptions were investigated.The experiment results showed as follows:on the condition of the presence of CTMAB,the maximum absorption of aluminum was at 558 nm with CAS as a indicating color reagent in the buffer solution of HAc-NaAc(pH=5.0).The Beer's law was well obeyed in the range of 0~15/L for aluminum,and the linear regression eqution was Y=0.049 1ρ- 0.032 9 and the correlation coefficient was 0.999 6.The method had been applied to the determination of content of aluminum in silicon-aluminum residue,the relative standard deviations were 1.31%~3.35%,and the recoveries were 98.86%~101.04%.

Key concepts: Reagent, Aluminium, Spectrophotometry, Silicon, Residue (chemistry), Chemistry, Buffer solution, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of content of aluminum in silicon-aluminum residue with spectrophotometry — Research Paper | ScholarLens