2008•Journal of the South China Agricultural UniversityRequires access

Determination of Nickel in Soil by Flame Atomic Absorption Spectrometry with Microwave Digestion

Xingguo Tian

Open publisher page 0 citations

Abstract

Soil samples were digested in an inclosed microwave system,then flame atomic absorption spectrometry was applied to determination of nickel in the samples.Compared with national standard method,the results tested by microwave digestion were almost consistent.But the proposed method was improved in digestion time and reagent.Under the optimum conditions,the detection limit was 0.015 4 mg/L with recoveries of 97.4%-103.0%.The relative standard deviation of determination was lower than 4.1%.

About this research paper

What this paper is about

Soil samples were digested in an inclosed microwave system,then flame atomic absorption spectrometry was applied to determination of nickel in the samples.Compared with national standard method,the results tested by microwave digestion were almost consistent.But the proposed method was improved in digestion time and reagent.Under the optimum conditions,the detection limit was 0.015 4 mg/L with recoveries of 97.4%-103.0%.The relative standard deviation of determination was lower than 4.1%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Soil samples were digested in an inclosed microwave system,then flame atomic absorption spectrometry was applied to determination of nickel in the samples.Compared with national standard method,the results tested by microwave digestion were almost consistent.But the proposed method was improved in digestion time and reagent.Under the optimum conditions,the detection limit was 0.015 4 mg/L with recoveries of 97.4%-103.0%.The relative standard deviation of determination was lower than 4.1%.

Key concepts: Microwave digestion, Atomic absorption spectroscopy, Detection limit, Nickel, Analytical Chemistry (journal), Microwave, Digestion (alchemy), Relative standard deviation

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Nickel in Soil by Flame Atomic Absorption Spectrometry with Microwave Digestion — Research Paper | ScholarLens