2013China Medical DevicesRequires access

Application Analysis of Low Dose Chest CT scan

Linlin Qian

Open publisher page 0 citations

Abstract

Objective To probe into the value of low dose chest CT in clinical application.Methods 100 cases are randomly classified into 2 groups.Each includes 18 males and 32 females.The height is between 1.60~1.78 m and the weight is between 50~80 kg.The tube current of regular group A is 90 mAs,and control group B is 70 mAs.The tube voltages are both 120 kv and the scanned images are compared by using t test and are supervised by 2 advanced doctors for blind peer review between the two groups.Results CTDI decreases by 23.3%,from 6.84 mGy to 5.32 mGy when the tube current changed from 90 mAs to 70 mAs.The average effective tube ball dose,total tube ball dose,and CT dose index volume are(75.83±4.92) mAs,(2092±128.14) mAs and(5.77±0.42) mGy in regular group A,and the data are(56.24±5.87) mAs,(1592±114.02) mAs and(4.29±0.69) mGy in low dose group.Both of them have statistical significance(t=20.62,t=35.41,t=5.48,p0.05).The image noises are(11.4±2.97) HU in standard group and(14.22±3.39) HU in low dose group,there is statistical significance is(t=6.71,p0.05).Conclusion The low dose chest CT can remarkably reduce the radiation dose,and provide satisfactory images for diagnosis.

About this research paper

What this paper is about

Objective To probe into the value of low dose chest CT in clinical application.Methods 100 cases are randomly classified into 2 groups.Each includes 18 males and 32 females.The height is between 1.60~1.78 m and the weight is between 50~80 kg.The tube current of regular group A is 90 mAs,and control group B is 70 mAs.The tube voltages are both 120 kv and the scanned images are compared by using t test and are supervised by 2 advanced doctors for blind peer review between the two groups.Results CTDI decreases by 23.3%,from 6.84 mGy to 5.32 mGy when the tube current changed from 90 mAs to 70 mAs.The average effective tube ball dose,total tube ball dose,and CT dose index volume are(75.83±4.92) mAs,(2092±128.14) mAs and(5.77±0.42) mGy in regular group A,and the data are(56.24±5.87) mAs,(1592±114.02) mAs and(4.29±0.69) mGy in low dose group.Both of them have statistical significance(t=20.62,t=35.41,t=5.48,p0.05).The image noises are(11.4±2.97) HU in standard group and(14.22±3.39) HU in low dose group,there is statistical significance is(t=6.71,p0.05).Conclusion The low dose chest CT can remarkably reduce the radiation dose,and provide satisfactory images for diagnosis.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To probe into the value of low dose chest CT in clinical application.Methods 100 cases are randomly classified into 2 groups.Each includes 18 males and 32 females.The height is between 1.60~1.78 m and the weight is between 50~80 kg.The tube current of regular group A is 90 mAs,and control group B is 70 mAs.The tube voltages are both 120 kv and the scanned images are compared by using t test and are supervised by 2 advanced doctors for blind peer review between the two groups.Results CTDI decreases by 23.3%,from 6.84 mGy to 5.32 mGy when the tube current changed from 90 mAs to 70 mAs.The average effective tube ball dose,total tube ball dose,and CT dose index volume are(75.83±4.92) mAs,(2092±128.14) mAs and(5.77±0.42) mGy in regular group A,and the data are(56.24±5.87) mAs,(1592±114.02) mAs and(4.29±0.69) mGy in low dose group.Both of them have statistical significance(t=20.62,t=35.41,t=5.48,p0.05).The image noises are(11.4±2.97) HU in standard group and(14.22±3.39) HU in low dose group,there is statistical significance is(t=6.71,p0.05).Conclusion The low dose chest CT can remarkably reduce the radiation dose,and provide satisfactory images for diagnosis.

Key concepts: Nuclear medicine, Statistical significance, Medicine, Effective dose (radiation), Radiation dose, Statistical analysis, Clinical significance, Radiology