2009•Gao dianya jishuRequires access

Corona Test for UHVAC Rigid Jumper

Peng Zongren

Open publisher page 3 citations

Abstract

The fittings of rigid jumpers are the most complex parts of transmission line construction, but their corona is more severe than normal fittings, especially for the UHV rigid jumper. So configuration and its corona problem of different type rigid jumpers must be researched. We figured out the electric field of rigid jumper under actual operation condition and the simplified simulation arrangement, and proposed a test model by simplified simulation arrangement and the correction factor. Moreover we proposed the standard voltage for UHV rigid jumper. By carrying out the corona test under actual conditions and the simplified simulation arrangement, the test method of simplified simulation arrangement is proved to be effective.

About this research paper

What this paper is about

The fittings of rigid jumpers are the most complex parts of transmission line construction, but their corona is more severe than normal fittings, especially for the UHV rigid jumper. So configuration and its corona problem of different type rigid jumpers must be researched. We figured out the electric field of rigid jumper under actual operation condition and the simplified simulation arrangement, and proposed a test model by simplified simulation arrangement and the correction factor. Moreover we proposed the standard voltage for UHV rigid jumper. By carrying out the corona test under actual conditions and the simplified simulation arrangement, the test method of simplified simulation arrangement is proved to be effective.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The fittings of rigid jumpers are the most complex parts of transmission line construction, but their corona is more severe than normal fittings, especially for the UHV rigid jumper. So configuration and its corona problem of different type rigid jumpers must be researched. We figured out the electric field of rigid jumper under actual operation condition and the simplified simulation arrangement, and proposed a test model by simplified simulation arrangement and the correction factor. Moreover we proposed the standard voltage for UHV rigid jumper. By carrying out the corona test under actual conditions and the simplified simulation arrangement, the test method of simplified simulation arrangement is proved to be effective.

Key concepts: Jumper, Corona (planetary geology), Structural engineering, Voltage, Corona discharge, Engineering, Corona ring, Simulation

Related papers

Back to paper searchBrowse research topicsOriginal source
Corona Test for UHVAC Rigid Jumper — Research Paper | ScholarLens