2011Metallurgical AnalysisRequires access

Determination of trace elements in electrolytic manganese metal by inductively coupled plasma mass spectrometry

Xie Hua-lin

Open publisher page 0 citations

Abstract

After electrolytic manganese metal sample was digested by HNO3+HCl with microwave,thirteen trace elements(Na,Mg,Ti,V,Co,Ni,Cu,Zn,As,Mo,Cd,Sb and Pb) in solution were determined simultaneously by inductively coupled plasma mass spectrometry(ICP-MS).The mass spectral interference was overcome by optimizing the instrumental operation parameters,selecting appropriate isotopes for testing elements and using correction equation of interference elements.The matrix interference was eliminated by using internal standard element.The results showed that the detection limits of eleven trace elements(Mg,V,Co,Ni,Cu,Zn,As,Mo,Cd,Sb and Pb) were 0.001-0.086 μg/L,and that of Na and Ti were 0.16-0.19 μg/L.The proposed method has been applied to the determination of electrolytic manganese metal sample.The results were consist with those obtained by other analytical methods with recoveries of standard addition of 95%-106% and relative standard deviation(RSD) less than 3.5 %.

About this research paper

What this paper is about

After electrolytic manganese metal sample was digested by HNO3+HCl with microwave,thirteen trace elements(Na,Mg,Ti,V,Co,Ni,Cu,Zn,As,Mo,Cd,Sb and Pb) in solution were determined simultaneously by inductively coupled plasma mass spectrometry(ICP-MS).The mass spectral interference was overcome by optimizing the instrumental operation parameters,selecting appropriate isotopes for testing elements and using correction equation of interference elements.The matrix interference was eliminated by using internal standard element.The results showed that the detection limits of eleven trace elements(Mg,V,Co,Ni,Cu,Zn,As,Mo,Cd,Sb and Pb) were 0.001-0.086 μg/L,and that of Na and Ti were 0.16-0.19 μg/L.The proposed method has been applied to the determination of electrolytic manganese metal sample.The results were consist with those obtained by other analytical methods with recoveries of standard addition of 95%-106% and relative standard deviation(RSD) less than 3.5 %.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

After electrolytic manganese metal sample was digested by HNO3+HCl with microwave,thirteen trace elements(Na,Mg,Ti,V,Co,Ni,Cu,Zn,As,Mo,Cd,Sb and Pb) in solution were determined simultaneously by inductively coupled plasma mass spectrometry(ICP-MS).The mass spectral interference was overcome by optimizing the instrumental operation parameters,selecting appropriate isotopes for testing elements and using correction equation of interference elements.The matrix interference was eliminated by using internal standard element.The results showed that the detection limits of eleven trace elements(Mg,V,Co,Ni,Cu,Zn,As,Mo,Cd,Sb and Pb) were 0.001-0.086 μg/L,and that of Na and Ti were 0.16-0.19 μg/L.The proposed method has been applied to the determination of electrolytic manganese metal sample.The results were consist with those obtained by other analytical methods with recoveries of standard addition of 95%-106% and relative standard deviation(RSD) less than 3.5 %.

Key concepts: Manganese, Inductively coupled plasma mass spectrometry, Chemistry, Analytical Chemistry (journal), Inductively coupled plasma, Standard addition, Metal, Microwave digestion

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of trace elements in electrolytic manganese metal by inductively coupled plasma mass spectrometry — Research Paper | ScholarLens