2009•Zhongguo huxi yu weizhong jianhu zazhiRequires access

The Diagnostic Value of the Fractional Exhaled Nitric Oxide for Asthma

Zhu Ta

Open publisher page 3 citations

Abstract

Objective To determine the diagnostic value of fractional exhaled nitric(FeNO) measurement in diagnosis of bronchial asthma.Methods The patients with unkown-cause respiratory symptoms including wheezing,cough,and breathlessness were enrolled from August to September in 2008.FeNO was measured by nitric oxide analyzer(NIOX;Aerocrine AB;Solna,Sweden).Bronchial challenge test(BCT) or bronchodilator test was defined as golden standard for asthma diagnosis.The value of FeNO was assessed and the optimal operating point of FeNO testing was determined by the means of the receiver operating characteristic(ROC) curves.Results A total of 101 patients were enrolled,in which 48 cases were diagnosed as asthma by positive yield in BCT(in 38 cases) or bronchodilator test(in 10 cases).The severity of airway hyperresponsiveness(AHR) judged by BCT was mild in 15 cases,moderate in 15 cases and severe in 8 cases.The levels of FeNO of asthma group were higher than those of non-asthma group [(68.19±43.00)ppb vs(19.52±10.60)ppb,P0.05].A linear correlation of FeNO with lnPD20FEV1 was revealed in the cases with AHR.Area under ROC curve was 0.9.The optimal diagnostic cutoff point was 36.5 ppb which was capable of differentiating asthma and non-asthma with sensitivity of 92.7%,specificity of 83.3%,positive predictive value of 79.17%,negative predictive value of 94.34% and accuracy of 87.13%.Conclusion FeNO test may be helpful in the diagnosis of asthma with high sensitivity and specificity.

About this research paper

What this paper is about

Objective To determine the diagnostic value of fractional exhaled nitric(FeNO) measurement in diagnosis of bronchial asthma.Methods The patients with unkown-cause respiratory symptoms including wheezing,cough,and breathlessness were enrolled from August to September in 2008.FeNO was measured by nitric oxide analyzer(NIOX;Aerocrine AB;Solna,Sweden).Bronchial challenge test(BCT) or bronchodilator test was defined as golden standard for asthma diagnosis.The value of FeNO was assessed and the optimal operating point of FeNO testing was determined by the means of the receiver operating characteristic(ROC) curves.Results A total of 101 patients were enrolled,in which 48 cases were diagnosed as asthma by positive yield in BCT(in 38 cases) or bronchodilator test(in 10 cases).The severity of airway hyperresponsiveness(AHR) judged by BCT was mild in 15 cases,moderate in 15 cases and severe in 8 cases.The levels of FeNO of asthma group were higher than those of non-asthma group [(68.19±43.00)ppb vs(19.52±10.60)ppb,P0.05].A linear correlation of FeNO with lnPD20FEV1 was revealed in the cases with AHR.Area under ROC curve was 0.9.The optimal diagnostic cutoff point was 36.5 ppb which was capable of differentiating asthma and non-asthma with sensitivity of 92.7%,specificity of 83.3%,positive predictive value of 79.17%,negative predictive value of 94.34% and accuracy of 87.13%.Conclusion FeNO test may be helpful in the diagnosis of asthma with high sensitivity and specificity.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To determine the diagnostic value of fractional exhaled nitric(FeNO) measurement in diagnosis of bronchial asthma.Methods The patients with unkown-cause respiratory symptoms including wheezing,cough,and breathlessness were enrolled from August to September in 2008.FeNO was measured by nitric oxide analyzer(NIOX;Aerocrine AB;Solna,Sweden).Bronchial challenge test(BCT) or bronchodilator test was defined as golden standard for asthma diagnosis.The value of FeNO was assessed and the optimal operating point of FeNO testing was determined by the means of the receiver operating characteristic(ROC) curves.Results A total of 101 patients were enrolled,in which 48 cases were diagnosed as asthma by positive yield in BCT(in 38 cases) or bronchodilator test(in 10 cases).The severity of airway hyperresponsiveness(AHR) judged by BCT was mild in 15 cases,moderate in 15 cases and severe in 8 cases.The levels of FeNO of asthma group were higher than those of non-asthma group [(68.19±43.00)ppb vs(19.52±10.60)ppb,P0.05].A linear correlation of FeNO with lnPD20FEV1 was revealed in the cases with AHR.Area under ROC curve was 0.9.The optimal diagnostic cutoff point was 36.5 ppb which was capable of differentiating asthma and non-asthma with sensitivity of 92.7%,specificity of 83.3%,positive predictive value of 79.17%,negative predictive value of 94.34% and accuracy of 87.13%.Conclusion FeNO test may be helpful in the diagnosis of asthma with high sensitivity and specificity.

Key concepts: Medicine, Exhaled nitric oxide, Asthma, Bronchodilator, Receiver operating characteristic, Internal medicine, Area under the curve, Bronchial hyperresponsiveness

Related papers

Back to paper searchBrowse research topicsOriginal source
The Diagnostic Value of the Fractional Exhaled Nitric Oxide for Asthma — Research Paper | ScholarLens