2012Shanxi Electric PowerRequires access

Study on Online Monitoring of the Mechanical Characteristics of Circuit Breaker in Switchgear

Song Jing-kai

Open publisher page 0 citations

Abstract

The online monitoring of the characteristics of circuit breaker in high voltage switchgear has been studied.The curve route of moving contact has been measured indirectly by using non-contact angular displacement sensor,which could effectively overcome the difficulties in installing conventional angular displacement sensor and linear displacement sensor.The opening and closing moment of static and moving contact has been identified by using the auxiliary contacts of circuit breaker with the help of experiment.The starting moment of the circuit breaker' opening and closing period has been clarified by using hall current sensors and their circuits.The parameters of circuit breaker's mechanical characteristics have been calculated by using DSP2812 as processor.

About this research paper

What this paper is about

The online monitoring of the characteristics of circuit breaker in high voltage switchgear has been studied.The curve route of moving contact has been measured indirectly by using non-contact angular displacement sensor,which could effectively overcome the difficulties in installing conventional angular displacement sensor and linear displacement sensor.The opening and closing moment of static and moving contact has been identified by using the auxiliary contacts of circuit breaker with the help of experiment.The starting moment of the circuit breaker' opening and closing period has been clarified by using hall current sensors and their circuits.The parameters of circuit breaker's mechanical characteristics have been calculated by using DSP2812 as processor.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The online monitoring of the characteristics of circuit breaker in high voltage switchgear has been studied.The curve route of moving contact has been measured indirectly by using non-contact angular displacement sensor,which could effectively overcome the difficulties in installing conventional angular displacement sensor and linear displacement sensor.The opening and closing moment of static and moving contact has been identified by using the auxiliary contacts of circuit breaker with the help of experiment.The starting moment of the circuit breaker' opening and closing period has been clarified by using hall current sensors and their circuits.The parameters of circuit breaker's mechanical characteristics have been calculated by using DSP2812 as processor.

Key concepts: Circuit breaker, Switchgear, Electrical engineering, Arc-fault circuit interrupter, Engineering, Displacement (psychology), Electronic circuit, Closing (real estate)

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on Online Monitoring of the Mechanical Characteristics of Circuit Breaker in Switchgear — Research Paper | ScholarLens