2007Advanced Technology of Electrical Engineering and EnergyRequires access

Design and application of high-capacity shunt hybrid active power filter

Zhou Ke

Open publisher page 0 citations

Abstract

According to the integrated requirements on harmonic elimination and reactive power compensation,the paper considers better filter performances and less cost of active power filter,and then forms a whole set of design methods for high-capacity injection type shunt hybrid active power filter.Its application in a smeltery's 220kV substation can meet the harmonic suppression requirement well and the effect is obvious for both the high performances and low cost.China has few applications of high-capacity shunt hybrid active power filter till now,hence the given parameter design method and engineering experience are useful for applications and research of other active power filter.

About this research paper

What this paper is about

According to the integrated requirements on harmonic elimination and reactive power compensation,the paper considers better filter performances and less cost of active power filter,and then forms a whole set of design methods for high-capacity injection type shunt hybrid active power filter.Its application in a smeltery's 220kV substation can meet the harmonic suppression requirement well and the effect is obvious for both the high performances and low cost.China has few applications of high-capacity shunt hybrid active power filter till now,hence the given parameter design method and engineering experience are useful for applications and research of other active power filter.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

According to the integrated requirements on harmonic elimination and reactive power compensation,the paper considers better filter performances and less cost of active power filter,and then forms a whole set of design methods for high-capacity injection type shunt hybrid active power filter.Its application in a smeltery's 220kV substation can meet the harmonic suppression requirement well and the effect is obvious for both the high performances and low cost.China has few applications of high-capacity shunt hybrid active power filter till now,hence the given parameter design method and engineering experience are useful for applications and research of other active power filter.

Key concepts: Active filter, Active power filter, AC power, Electronic engineering, Shunt (medical), Engineering, Control theory (sociology), Computer science