2010Yibiao jishu yu chuanganqiRequires access

Design of Remote Controller for Inverter Based on Modbus Protocol

Xiaoqian Zhu

Open publisher page 0 citations

Abstract

For the inconvenient operation of the motor and operating room,this paper developed a remote controller,used the Modbus communication protocol through the double serial port,connected the inverter and the control system.In the way of host-slaver through the RS-485 bus network constitutes a distributed system control of multiple inverters,and achieved the process data,electric motor movement conditions real-time monitoring goal.The paper elaborated based on the Modbus communication protocol remote controller's hardware composition and the software establishment and the characteristic application.

About this research paper

What this paper is about

For the inconvenient operation of the motor and operating room,this paper developed a remote controller,used the Modbus communication protocol through the double serial port,connected the inverter and the control system.In the way of host-slaver through the RS-485 bus network constitutes a distributed system control of multiple inverters,and achieved the process data,electric motor movement conditions real-time monitoring goal.The paper elaborated based on the Modbus communication protocol remote controller's hardware composition and the software establishment and the characteristic application.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

For the inconvenient operation of the motor and operating room,this paper developed a remote controller,used the Modbus communication protocol through the double serial port,connected the inverter and the control system.In the way of host-slaver through the RS-485 bus network constitutes a distributed system control of multiple inverters,and achieved the process data,electric motor movement conditions real-time monitoring goal.The paper elaborated based on the Modbus communication protocol remote controller's hardware composition and the software establishment and the characteristic application.

Key concepts: Modbus, RS-485, Protocol (science), Controller (irrigation), Embedded system, Inverter, Software, Serial port

Related papers

Back to paper searchBrowse research topicsOriginal source
Design of Remote Controller for Inverter Based on Modbus Protocol — Research Paper | ScholarLens