2010Zhongguo linchuang jiepouxue zazhiRequires access

The radiographic study and clinical significance of femoral offset

Hua Jiang

Open publisher page 0 citations

Abstract

Objective To investage the range of femoral offset and explore its clinical significance.Methods 100 cases of normal anteroposterior hip joints radiographic image were measured.Parameters included femoral offset,abductor lever arm,body weight lever arm,femoral head diameter,neck-shaft angle,the width of bone medullary cavity at the plane of lesser trochanter,20 mm above and below the lesser trochanter,diameter of the narrow cavity and canal flare index(CFI).The correlation between femoral offset and other anatomical parameters in femur were explored by simple correlation analysis.The proximal femoral parameters between Chinese and the Western were compared.Results The range of femoral offset was(36.64±5.31)mm.Femoral offset and abductor lever arm was positively correlated(r=0.73,P0.01).Femoral offset was negatively correlated neck-shaft angle(r=-0.46,P0.01).There were no significance correlation between femoral offset and other anatomical parameters in femur.There was a significant difference in the diameter of the femoral head,neck-shaft angle,femoral offset,abductor lever arm between men and women(P 0.05).There was a significant difference in neck-shaft angle,femoral offset between Chinese and the Western(P0.01).Conclusions The range of femoral offset was(36.64±5.31) mm.Restoration of femoral offset can recover the length of abductor lever arm and restore the biomechanics of the hip.

About this research paper

What this paper is about

Objective To investage the range of femoral offset and explore its clinical significance.Methods 100 cases of normal anteroposterior hip joints radiographic image were measured.Parameters included femoral offset,abductor lever arm,body weight lever arm,femoral head diameter,neck-shaft angle,the width of bone medullary cavity at the plane of lesser trochanter,20 mm above and below the lesser trochanter,diameter of the narrow cavity and canal flare index(CFI).The correlation between femoral offset and other anatomical parameters in femur were explored by simple correlation analysis.The proximal femoral parameters between Chinese and the Western were compared.Results The range of femoral offset was(36.64±5.31)mm.Femoral offset and abductor lever arm was positively correlated(r=0.73,P0.01).Femoral offset was negatively correlated neck-shaft angle(r=-0.46,P0.01).There were no significance correlation between femoral offset and other anatomical parameters in femur.There was a significant difference in the diameter of the femoral head,neck-shaft angle,femoral offset,abductor lever arm between men and women(P 0.05).There was a significant difference in neck-shaft angle,femoral offset between Chinese and the Western(P0.01).Conclusions The range of femoral offset was(36.64±5.31) mm.Restoration of femoral offset can recover the length of abductor lever arm and restore the biomechanics of the hip.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To investage the range of femoral offset and explore its clinical significance.Methods 100 cases of normal anteroposterior hip joints radiographic image were measured.Parameters included femoral offset,abductor lever arm,body weight lever arm,femoral head diameter,neck-shaft angle,the width of bone medullary cavity at the plane of lesser trochanter,20 mm above and below the lesser trochanter,diameter of the narrow cavity and canal flare index(CFI).The correlation between femoral offset and other anatomical parameters in femur were explored by simple correlation analysis.The proximal femoral parameters between Chinese and the Western were compared.Results The range of femoral offset was(36.64±5.31)mm.Femoral offset and abductor lever arm was positively correlated(r=0.73,P0.01).Femoral offset was negatively correlated neck-shaft angle(r=-0.46,P0.01).There were no significance correlation between femoral offset and other anatomical parameters in femur.There was a significant difference in the diameter of the femoral head,neck-shaft angle,femoral offset,abductor lever arm between men and women(P 0.05).There was a significant difference in neck-shaft angle,femoral offset between Chinese and the Western(P0.01).Conclusions The range of femoral offset was(36.64±5.31) mm.Restoration of femoral offset can recover the length of abductor lever arm and restore the biomechanics of the hip.

Key concepts: Femur, Medicine, Femoral head, Lesser Trochanter, Femoral neck, Greater trochanter, Lever, Anatomy

Related papers

Back to paper searchBrowse research topicsOriginal source
The radiographic study and clinical significance of femoral offset — Research Paper | ScholarLens