Content Determination of Plumbm and Cadmium in Pericarpium Trichosanthis by Graphite Furnace Atomic Absorption Spectrometry
Xiaohua Wang
Abstract
Xiaohua Wang
Abstract
Objective: To establish a method for determination of plumbm(Pb) and cadmium(Cd) in pericarpium trichosanthis,and the content of plumbm(Pb) and cadmium(Cd) in pericarpium trichosanthis from 5 different origins were determined.Method: Microwave digestion was used to digest the samples and graphite furnace atomic absorption spectrometry was adopted for the content determination of Pb and Cd in samples.Result: The calibration curves were linear in the range of 0.0-80.0 μg.L-1 for plumbum(r = 0.999 1);the average recovery was 94.2%(n = 5,RSD 1.4%).The calibration curves were linear in the range of 0.0-10.0 μg.L-1 for cadmium(r = 0.999 2);the average recovery was 94.0%(n = 5,RSD 1.9%).The content of Pb and Cd was 0.814 and 0.057 mg.kg-1(Anhui),0.919 and 0.114 mg.kg-1(Zhejiang),0.989 and 0.120 mg.kg-1(Hebei),0.745 and 0.042 mg.kg-1(Shandong),1.244 and 0.089 mg.kg-1(Jiangsu).Conclusion: Harmful heavy metals have been detected in pericarpium trichosanthis,which is in line with the limitation stated in the Green Trade Standard for Medicinal Plant and Preparations(Pb≤5.0 mg.kg-1,Cd ≤0.3 mg.kg-1).This method is simple,accurate and suitable for the determination of heavy metals in pericarpium trichosanthis.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective: To establish a method for determination of plumbm(Pb) and cadmium(Cd) in pericarpium trichosanthis,and the content of plumbm(Pb) and cadmium(Cd) in pericarpium trichosanthis from 5 different origins were determined.Method: Microwave digestion was used to digest the samples and graphite furnace atomic absorption spectrometry was adopted for the content determination of Pb and Cd in samples.Result: The calibration curves were linear in the range of 0.0-80.0 μg.L-1 for plumbum(r = 0.999 1);the average recovery was 94.2%(n = 5,RSD 1.4%).The calibration curves were linear in the range of 0.0-10.0 μg.L-1 for cadmium(r = 0.999 2);the average recovery was 94.0%(n = 5,RSD 1.9%).The content of Pb and Cd was 0.814 and 0.057 mg.kg-1(Anhui),0.919 and 0.114 mg.kg-1(Zhejiang),0.989 and 0.120 mg.kg-1(Hebei),0.745 and 0.042 mg.kg-1(Shandong),1.244 and 0.089 mg.kg-1(Jiangsu).Conclusion: Harmful heavy metals have been detected in pericarpium trichosanthis,which is in line with the limitation stated in the Green Trade Standard for Medicinal Plant and Preparations(Pb≤5.0 mg.kg-1,Cd ≤0.3 mg.kg-1).This method is simple,accurate and suitable for the determination of heavy metals in pericarpium trichosanthis.
Key concepts: Graphite furnace atomic absorption, Cadmium, Microwave digestion, Calibration curve, Chemistry, Atomic absorption spectroscopy, Standard addition, Heavy metals