2013Food ScienceRequires access

Application of Inductively Coupled Plasma Mass Spectrometry(ICP-MS) for Determination of 28 Trace Elements in Chinese Liquor

Jia Zhang

Open publisher page 2 citations

Abstract

This paper describes a simple method for the determination of 28 micro-elements including Ag,Cd,Cs,Ba,Li,Be,Na,Mg,Al,K,Ca,V,Cr,Mn,Fe,Co,Ni,Cu,Zn,Ga,As,Se,Tl,Pb,Bi,U,Rb,and Sr in Chinese liquor by using inductively coupled plasma mass spectrometry(ICP-MS).For digestion of samples,10 mL of a mixture of HNO3 with HClO4(4:1,V/V) was used.The results revealed that the method had some advantages,such as simple sample pretreatment,fast analysis,low detection limit,high precision and accuracy,and wide linear dynamic range(0–300 μg/L for 21 of these micro-elements,0–30 μg/L for the rest).The recovery rates for all the micro-elements were between 85.19% and 104.01% with RSD less than 4.7%.This method can completely meet the requirements for determination of the 28 micro-elements in Chinese liquor.

About this research paper

What this paper is about

This paper describes a simple method for the determination of 28 micro-elements including Ag,Cd,Cs,Ba,Li,Be,Na,Mg,Al,K,Ca,V,Cr,Mn,Fe,Co,Ni,Cu,Zn,Ga,As,Se,Tl,Pb,Bi,U,Rb,and Sr in Chinese liquor by using inductively coupled plasma mass spectrometry(ICP-MS).For digestion of samples,10 mL of a mixture of HNO3 with HClO4(4:1,V/V) was used.The results revealed that the method had some advantages,such as simple sample pretreatment,fast analysis,low detection limit,high precision and accuracy,and wide linear dynamic range(0–300 μg/L for 21 of these micro-elements,0–30 μg/L for the rest).The recovery rates for all the micro-elements were between 85.19% and 104.01% with RSD less than 4.7%.This method can completely meet the requirements for determination of the 28 micro-elements in Chinese liquor.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper describes a simple method for the determination of 28 micro-elements including Ag,Cd,Cs,Ba,Li,Be,Na,Mg,Al,K,Ca,V,Cr,Mn,Fe,Co,Ni,Cu,Zn,Ga,As,Se,Tl,Pb,Bi,U,Rb,and Sr in Chinese liquor by using inductively coupled plasma mass spectrometry(ICP-MS).For digestion of samples,10 mL of a mixture of HNO3 with HClO4(4:1,V/V) was used.The results revealed that the method had some advantages,such as simple sample pretreatment,fast analysis,low detection limit,high precision and accuracy,and wide linear dynamic range(0–300 μg/L for 21 of these micro-elements,0–30 μg/L for the rest).The recovery rates for all the micro-elements were between 85.19% and 104.01% with RSD less than 4.7%.This method can completely meet the requirements for determination of the 28 micro-elements in Chinese liquor.

Key concepts: Inductively coupled plasma mass spectrometry, Chemistry, Detection limit, Inductively coupled plasma, Mass spectrometry, Analytical Chemistry (journal), Recovery rate, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Application of Inductively Coupled Plasma Mass Spectrometry(ICP-MS) for Determination of 28 Trace Elements in Chinese Liquor — Research Paper | ScholarLens