2010•Food ScienceRequires access

Electronic Nose for Measurement of Freshness Change of Chilled Pork during Storage at Different Temperatures

Zheng Jing-zhou

Open publisher page 3 citations

Abstract

Electronic nose was used to measure the freshness change of chilled pork during storage at-18,0,4,10 or 20 ℃.Injection volume of minced samples was optimized to be 1500 μL.Principal component analysis(PCA) of volatile odor of chilled pork was conducted.Electronic nose output signal was plotted as a function of storage time to estimate shelf-life of chilled pork stored at different temperatures.Partial least squares regression(PLS-regression) was employed to analyze correlation between electronic nose output signal and sensory evaluation score of volatile odor of chilled pork stored at 4 or 20 ℃.Results showed that there was a significant difference in volatile odor of chilled pork stored for different time at-18,0,4,10 or 20 ℃.Higher storage temperature resulted in earlier occurrence of significant decrease of freshness.The shelf-life of chilled pork stored at the above temperatures was 336,180,72,48 h and 18 h,respectively.The correlation coefficients between electronic nose output signal and sensory evaluation score of volatile odor of chilled pork stored at 4 and 20 ℃ were as high as 0.9982 and 0.9998,respectively,demonstrating that electronic nose is a reliable alternative to sensory evaluation for analysis of volatile odor of chilled pork.Electronic nose sensors TA/2,T40/1,T40/2,P30/2,P40/1,P10/2 and P10/1 were all found to give excellent specific responses to various characteristic odors of pork.

About this research paper

What this paper is about

Electronic nose was used to measure the freshness change of chilled pork during storage at-18,0,4,10 or 20 ℃.Injection volume of minced samples was optimized to be 1500 μL.Principal component analysis(PCA) of volatile odor of chilled pork was conducted.Electronic nose output signal was plotted as a function of storage time to estimate shelf-life of chilled pork stored at different temperatures.Partial least squares regression(PLS-regression) was employed to analyze correlation between electronic nose output signal and sensory evaluation score of volatile odor of chilled pork stored at 4 or 20 ℃.Results showed that there was a significant difference in volatile odor of chilled pork stored for different time at-18,0,4,10 or 20 ℃.Higher storage temperature resulted in earlier occurrence of significant decrease of freshness.The shelf-life of chilled pork stored at the above temperatures was 336,180,72,48 h and 18 h,respectively.The correlation coefficients between electronic nose output signal and sensory evaluation score of volatile odor of chilled pork stored at 4 and 20 ℃ were as high as 0.9982 and 0.9998,respectively,demonstrating that electronic nose is a reliable alternative to sensory evaluation for analysis of volatile odor of chilled pork.Electronic nose sensors TA/2,T40/1,T40/2,P30/2,P40/1,P10/2 and P10/1 were all found to give excellent specific responses to various characteristic odors of pork.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Electronic nose was used to measure the freshness change of chilled pork during storage at-18,0,4,10 or 20 ℃.Injection volume of minced samples was optimized to be 1500 μL.Principal component analysis(PCA) of volatile odor of chilled pork was conducted.Electronic nose output signal was plotted as a function of storage time to estimate shelf-life of chilled pork stored at different temperatures.Partial least squares regression(PLS-regression) was employed to analyze correlation between electronic nose output signal and sensory evaluation score of volatile odor of chilled pork stored at 4 or 20 ℃.Results showed that there was a significant difference in volatile odor of chilled pork stored for different time at-18,0,4,10 or 20 ℃.Higher storage temperature resulted in earlier occurrence of significant decrease of freshness.The shelf-life of chilled pork stored at the above temperatures was 336,180,72,48 h and 18 h,respectively.The correlation coefficients between electronic nose output signal and sensory evaluation score of volatile odor of chilled pork stored at 4 and 20 ℃ were as high as 0.9982 and 0.9998,respectively,demonstrating that electronic nose is a reliable alternative to sensory evaluation for analysis of volatile odor of chilled pork.Electronic nose sensors TA/2,T40/1,T40/2,P30/2,P40/1,P10/2 and P10/1 were all found to give excellent specific responses to various characteristic odors of pork.

Key concepts: Electronic nose, Odor, Food science, Chemistry, Shelf life, Partial least squares regression, Mathematics, Computer science

Related papers

Back to paper searchBrowse research topicsOriginal source
Electronic Nose for Measurement of Freshness Change of Chilled Pork during Storage at Different Temperatures — Research Paper | ScholarLens