2009Acta Physica SinicaRequires access

High resolution fast digital photoacoustic CT for breast cancer diagnosis

Moe Key

Open publisher page 0 citations

Abstract

Photoacoustic imaging combines advantages of both ultrasound imaging and optical imaging to provide high ultrasonic resolution and high optical contrast in noninvasive medical images.A photoacoustic computer tomography(PCT) system with a focused digital phased array transducer is proposed.In particular each element of the transducer array has a thin cylindrical ultrasonic lens to select 2D image plane and suppress the out-of-plane signals to realize photoacoustic computed tomography.A fast full-view photoacoustic imaging system for visualizing tissue structures using a linear transducer array with combined scan,whies;detects photoacoustic signals by combined electronic and mechanical scanning.An improved limited-field filtered back projection algorithm with directivity factors was applied to reconstruct the optical absorption distribution and further improve the lateral resolution.In the experiment,the spatial resolution of this imaging system is determined as 0.2?mm,and the slice resolution of Z axis is 1.5?mm.Mechanical step scanning was performed, leading to a measurement time of 6.4 seconds per position,and a total scan duration of 150 seconds to obtain the two-dimensional photoacoustic image.High spatial resolution of 2D photoacoustic vascular image and quasi-3D photoacoustic CT for breast cancer imaging are achicned.The experimental results demonstrate that this method and imaging system can realize the high resolution photoacoustic tomography wtich can be applied to noninvasive detection of early breast cancer.

About this research paper

What this paper is about

Photoacoustic imaging combines advantages of both ultrasound imaging and optical imaging to provide high ultrasonic resolution and high optical contrast in noninvasive medical images.A photoacoustic computer tomography(PCT) system with a focused digital phased array transducer is proposed.In particular each element of the transducer array has a thin cylindrical ultrasonic lens to select 2D image plane and suppress the out-of-plane signals to realize photoacoustic computed tomography.A fast full-view photoacoustic imaging system for visualizing tissue structures using a linear transducer array with combined scan,whies;detects photoacoustic signals by combined electronic and mechanical scanning.An improved limited-field filtered back projection algorithm with directivity factors was applied to reconstruct the optical absorption distribution and further improve the lateral resolution.In the experiment,the spatial resolution of this imaging system is determined as 0.2?mm,and the slice resolution of Z axis is 1.5?mm.Mechanical step scanning was performed, leading to a measurement time of 6.4 seconds per position,and a total scan duration of 150 seconds to obtain the two-dimensional photoacoustic image.High spatial resolution of 2D photoacoustic vascular image and quasi-3D photoacoustic CT for breast cancer imaging are achicned.The experimental results demonstrate that this method and imaging system can realize the high resolution photoacoustic tomography wtich can be applied to noninvasive detection of early breast cancer.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Photoacoustic imaging combines advantages of both ultrasound imaging and optical imaging to provide high ultrasonic resolution and high optical contrast in noninvasive medical images.A photoacoustic computer tomography(PCT) system with a focused digital phased array transducer is proposed.In particular each element of the transducer array has a thin cylindrical ultrasonic lens to select 2D image plane and suppress the out-of-plane signals to realize photoacoustic computed tomography.A fast full-view photoacoustic imaging system for visualizing tissue structures using a linear transducer array with combined scan,whies;detects photoacoustic signals by combined electronic and mechanical scanning.An improved limited-field filtered back projection algorithm with directivity factors was applied to reconstruct the optical absorption distribution and further improve the lateral resolution.In the experiment,the spatial resolution of this imaging system is determined as 0.2?mm,and the slice resolution of Z axis is 1.5?mm.Mechanical step scanning was performed, leading to a measurement time of 6.4 seconds per position,and a total scan duration of 150 seconds to obtain the two-dimensional photoacoustic image.High spatial resolution of 2D photoacoustic vascular image and quasi-3D photoacoustic CT for breast cancer imaging are achicned.The experimental results demonstrate that this method and imaging system can realize the high resolution photoacoustic tomography wtich can be applied to noninvasive detection of early breast cancer.

Key concepts: Photoacoustic Doppler effect, Transducer, Ultrasonic sensor, Materials science, Photoacoustic effect, Tomography, Photoacoustic imaging in biomedicine, Optics

Related papers

Back to paper searchBrowse research topicsOriginal source
High resolution fast digital photoacoustic CT for breast cancer diagnosis — Research Paper | ScholarLens