2006•PubMedRequires access

[The impact of expansion of sirolimus eluting stent on intimal hyperplasia: an intravascular ultrasound study].

Ruiyan Zhang, Weifeng Shen, Jian-sheng Zhang, Zhen-kun Yang, Qi Zhang, Jian Hu, Yuehua Fang

Open publisher page 0 citations

Abstract

OBJECTIVE: To assess the impact of expansion grade of sirolimus eluting stent on intimal hyperplasia with intravascular ultrasound (IVUS). METHODS: A total of 75 patients implanted with sirolimus eluting stents for at least 8 months were enrolled in this study and IVUS could be performed in 76 stents of 73 patients and 2 patients were excluded due to total coronary occlusion. External elastic membrane (EEM) cross-sectional areas (CSA) at stent inlet and outlet, at in-stent minimal CSA; in-stent CSA, cavity CSA, intimal area (in-stent area-cavity area), maximal and minimal diameter of stent, and symmetry index of stent (minimal diameter of stent/maximal diameter of stent) were measured. RESULT: Five out of 76 stents of 73 patients developed intimal hyperplasia and intimal proliferation was inhibited by sirolimus eluting stent in patients with either minimal stent CSA/EEM CSA < 0.5 (n = 56) or >or= 0.5 (n = 20), minimal stent CSA/reference CSA < 0.9 (n = 44) or >or= 0.9 (n = 32), minimal stent CSA < 5 mm(2) (n = 25) or CSA >or= 5 mm(2) (n = 51), symmetry index of stent at minimal CSA of stent < 0.9 (n = 37) or >or= 0.9 (n = 39) during IVUS follow up. CONCLUSION: Sirolimus eluting stent inhibited intimal hyperplasia independent of stent expansion grade.

About this research paper

What this paper is about

OBJECTIVE: To assess the impact of expansion grade of sirolimus eluting stent on intimal hyperplasia with intravascular ultrasound (IVUS). METHODS: A total of 75 patients implanted with sirolimus eluting stents for at least 8 months were enrolled in this study and IVUS could be performed in 76 stents of 73 patients and 2 patients were excluded due to total coronary occlusion. External elastic membrane (EEM) cross-sectional areas (CSA) at stent inlet and outlet, at in-stent minimal CSA; in-stent CSA, cavity CSA, intimal area (in-stent area-cavity area), maximal and minimal diameter of stent, and symmetry index of stent (minimal diameter of stent/maximal diameter of stent) were measured. RESULT: Five out of 76 stents of 73 patients developed intimal hyperplasia and intimal proliferation was inhibited by sirolimus eluting stent in patients with either minimal stent CSA/EEM CSA < 0.5 (n = 56) or >or= 0.5 (n = 20), minimal stent CSA/reference CSA < 0.9 (n = 44) or >or= 0.9 (n = 32), minimal stent CSA < 5 mm(2) (n = 25) or CSA >or= 5 mm(2) (n = 51), symmetry index of stent at minimal CSA of stent < 0.9 (n = 37) or >or= 0.9 (n = 39) during IVUS follow up. CONCLUSION: Sirolimus eluting stent inhibited intimal hyperplasia independent of stent expansion grade.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To assess the impact of expansion grade of sirolimus eluting stent on intimal hyperplasia with intravascular ultrasound (IVUS). METHODS: A total of 75 patients implanted with sirolimus eluting stents for at least 8 months were enrolled in this study and IVUS could be performed in 76 stents of 73 patients and 2 patients were excluded due to total coronary occlusion. External elastic membrane (EEM) cross-sectional areas (CSA) at stent inlet and outlet, at in-stent minimal CSA; in-stent CSA, cavity CSA, intimal area (in-stent area-cavity area), maximal and minimal diameter of stent, and symmetry index of stent (minimal diameter of stent/maximal diameter of stent) were measured. RESULT: Five out of 76 stents of 73 patients developed intimal hyperplasia and intimal proliferation was inhibited by sirolimus eluting stent in patients with either minimal stent CSA/EEM CSA < 0.5 (n = 56) or >or= 0.5 (n = 20), minimal stent CSA/reference CSA < 0.9 (n = 44) or >or= 0.9 (n = 32), minimal stent CSA < 5 mm(2) (n = 25) or CSA >or= 5 mm(2) (n = 51), symmetry index of stent at minimal CSA of stent < 0.9 (n = 37) or >or= 0.9 (n = 39) during IVUS follow up. CONCLUSION: Sirolimus eluting stent inhibited intimal hyperplasia independent of stent expansion grade.

Key concepts: Medicine, Stent, Intravascular ultrasound, Intimal hyperplasia, Sirolimus, Radiology, Surgery, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
[The impact of expansion of sirolimus eluting stent on intimal hyperplasia: an intravascular ultrasound study]. — Research Paper | ScholarLens