2008Journal of Tongji UniversityRequires access

Application of Safe-Cut~(TM) balloon in coronary artery in-stent restenosis

Jiang Jin-fa

Open publisher page 0 citations

Abstract

Objective To assess the safety and therapeutical efficiency of dual-wire balloon using in treating coronary artery in-stent restenosis.Methods Eighty-two lesions out of 70 patients with more than 70% restenosis were included after coronary angiography.Dual-wire balloon angioplasty was performed in these lesions.Quantitative coronary angiography(QCA)analysis was used to analyze dilatation efficiency and clinical follow-up visit was also performed.Results Success rate of dilatation was 100%.QCA analysis indicated that target minimum lumen diameter(MLD)significantly increased from(0.76±0.52)mm to(2.64±0.41)mm(P0.001) while diameter stenosis(DS)decreased significantly from 87.7%±8.4% to 8.6%±6.9%(P0.001).No cardiovascular events occurred during the follow-up visit.Conclusion Dual-wire balloon angioplasty is effective and safe for the treatment of in-stent restenosis.

About this research paper

What this paper is about

Objective To assess the safety and therapeutical efficiency of dual-wire balloon using in treating coronary artery in-stent restenosis.Methods Eighty-two lesions out of 70 patients with more than 70% restenosis were included after coronary angiography.Dual-wire balloon angioplasty was performed in these lesions.Quantitative coronary angiography(QCA)analysis was used to analyze dilatation efficiency and clinical follow-up visit was also performed.Results Success rate of dilatation was 100%.QCA analysis indicated that target minimum lumen diameter(MLD)significantly increased from(0.76±0.52)mm to(2.64±0.41)mm(P0.001) while diameter stenosis(DS)decreased significantly from 87.7%±8.4% to 8.6%±6.9%(P0.001).No cardiovascular events occurred during the follow-up visit.Conclusion Dual-wire balloon angioplasty is effective and safe for the treatment of in-stent restenosis.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To assess the safety and therapeutical efficiency of dual-wire balloon using in treating coronary artery in-stent restenosis.Methods Eighty-two lesions out of 70 patients with more than 70% restenosis were included after coronary angiography.Dual-wire balloon angioplasty was performed in these lesions.Quantitative coronary angiography(QCA)analysis was used to analyze dilatation efficiency and clinical follow-up visit was also performed.Results Success rate of dilatation was 100%.QCA analysis indicated that target minimum lumen diameter(MLD)significantly increased from(0.76±0.52)mm to(2.64±0.41)mm(P0.001) while diameter stenosis(DS)decreased significantly from 87.7%±8.4% to 8.6%±6.9%(P0.001).No cardiovascular events occurred during the follow-up visit.Conclusion Dual-wire balloon angioplasty is effective and safe for the treatment of in-stent restenosis.

Key concepts: Restenosis, Medicine, Balloon, Angioplasty, Stent, Lumen (anatomy), Stenosis, Cardiology