2002•Metallurgical PowerRequires access

Analysis of Effect of Water Hammer on Blast Furnace Cooling Water Systemof Closed Circuit

Chen Guo-sheng

Open publisher page 0 citations

Abstract

The characteristic method was used to make a computative simulative analysis of the effect of water hammer after shutdown of the pump on the soft water cooling system of closed circuit for No.1 Blast Furnace of Wuhan Iron Steel Co. Pressure variation of water hammer of the cooling water system and its effect on the system were analyzed during emergent shutdown of the pump due to shutoff of power. It was suggested that expansion tanks should be used to avoid the above incident. Some problems needing attention are given. This provides technical basis for the system's optimum design and safety operation.

About this research paper

What this paper is about

The characteristic method was used to make a computative simulative analysis of the effect of water hammer after shutdown of the pump on the soft water cooling system of closed circuit for No.1 Blast Furnace of Wuhan Iron Steel Co. Pressure variation of water hammer of the cooling water system and its effect on the system were analyzed during emergent shutdown of the pump due to shutoff of power. It was suggested that expansion tanks should be used to avoid the above incident. Some problems needing attention are given. This provides technical basis for the system's optimum design and safety operation.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The characteristic method was used to make a computative simulative analysis of the effect of water hammer after shutdown of the pump on the soft water cooling system of closed circuit for No.1 Blast Furnace of Wuhan Iron Steel Co. Pressure variation of water hammer of the cooling water system and its effect on the system were analyzed during emergent shutdown of the pump due to shutoff of power. It was suggested that expansion tanks should be used to avoid the above incident. Some problems needing attention are given. This provides technical basis for the system's optimum design and safety operation.

Key concepts: Water hammer, Water cooling, Shutdown, Nuclear engineering, Engineering, Power (physics), Blast furnace, Mechanical engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis of Effect of Water Hammer on Blast Furnace Cooling Water Systemof Closed Circuit — Research Paper | ScholarLens