2011Xiandai shipin kejiRequires access

Determination of Para Red and Sudan Red Dyes in Food by Reversed Phase High Performance Liquid Chromatography

Yan Chen

Open publisher page 0 citations

Abstract

A method was developed for the determination of Para Red and Sudan dyes in food by reversed phase-high performance liquid chromatography(RP-HPLC) with a new simple extract system.Sample was extracted from food with methanol-acetonitrile-acetone.The analysis was performed on a Shiseido C18 column(150 mm×4.6mm i.d.,5μm),with water-acetonitrile as the mobile phase at a flow rate of 1.0mL/min.Detection was carried out at the wavelength of 500nm and confirmed by spectra.All of the six compounds demonstrated good linear relationship(r=0.9998).The limit of detection(LOD)(spiked at the levels of 0.5~5.0 μg/mL) was 0.1 mg/kg.The average recoveries for all six dyes were ranged from 85%~106%,and the relative standard deviations were form 2.14%~4.82%.The method is sensitive,reliable and can be applied for the analysis of Para Red and Sudan dyes in food.

About this research paper

What this paper is about

A method was developed for the determination of Para Red and Sudan dyes in food by reversed phase-high performance liquid chromatography(RP-HPLC) with a new simple extract system.Sample was extracted from food with methanol-acetonitrile-acetone.The analysis was performed on a Shiseido C18 column(150 mm×4.6mm i.d.,5μm),with water-acetonitrile as the mobile phase at a flow rate of 1.0mL/min.Detection was carried out at the wavelength of 500nm and confirmed by spectra.All of the six compounds demonstrated good linear relationship(r=0.9998).The limit of detection(LOD)(spiked at the levels of 0.5~5.0 μg/mL) was 0.1 mg/kg.The average recoveries for all six dyes were ranged from 85%~106%,and the relative standard deviations were form 2.14%~4.82%.The method is sensitive,reliable and can be applied for the analysis of Para Red and Sudan dyes in food.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method was developed for the determination of Para Red and Sudan dyes in food by reversed phase-high performance liquid chromatography(RP-HPLC) with a new simple extract system.Sample was extracted from food with methanol-acetonitrile-acetone.The analysis was performed on a Shiseido C18 column(150 mm×4.6mm i.d.,5μm),with water-acetonitrile as the mobile phase at a flow rate of 1.0mL/min.Detection was carried out at the wavelength of 500nm and confirmed by spectra.All of the six compounds demonstrated good linear relationship(r=0.9998).The limit of detection(LOD)(spiked at the levels of 0.5~5.0 μg/mL) was 0.1 mg/kg.The average recoveries for all six dyes were ranged from 85%~106%,and the relative standard deviations were form 2.14%~4.82%.The method is sensitive,reliable and can be applied for the analysis of Para Red and Sudan dyes in food.

Key concepts: Chromatography, Detection limit, Acetonitrile, Chemistry, Acetone, High-performance liquid chromatography, Relative standard deviation, Methanol

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Para Red and Sudan Red Dyes in Food by Reversed Phase High Performance Liquid Chromatography — Research Paper | ScholarLens