2006PubMedRequires access

[Evaluation of CT, MRI and PET-CT in detecting retropharyngeal lymph node metastasis in nasopharyngeal carcinoma].

Yong Su, Chong Zhao, Chuan Xie, Li Xia Lu, Ying Sun, Fei Han, Hu bing Wu, Nian Ji Cui, Zong Yuan Zeng, Tai Xiang Lu

Open publisher page 14 citations

Abstract

BACKGROUND & OBJECTIVE: At present, the detection of retropharyngeal lymph node (RLN) metastasis in nasopharyngeal carcinoma (NPC) mainly depends on imaging, but the diagnosis criteria are controversial. Recently, the 18F-fluoro-2-deoxy-D-glucose positron emission tomography ((18)FDG-PET-CT) has been widely applied in diagnosing cancer. This study was to evaluate CT, MRI, and (18)FDG-PET-CT in detecting RLN metastasis of NPC, and explore the imaging diagnosis criteria. METHODS: From Dec. 2003 to Aug. 2005, 53 consecutive patients with NPC treated in Cancer Center of Sun Yat-sen University were enrolled. Contrast enhanced CT, MRI, and (18)FDG-PET-CT were performed on bilateral RLNs of the patients within 10 days before treatment. The diagnosis criteria of RLN metastasis for CT and MRI included single node with maximum diameter of > or =4 mm, and the presence of central necrosis or ringed enhancement; the criteria for (18)FDG-PET-CT included abnormal accumulation of irradiation in the RLN with the standard uptake value (SUV) of > or =2.5. Considering the response of RLN to clinical treatment, the differences of CT, MRI, and PET-CT in detecting RLN metastasis were compared. RESULTS: Among the 106 intropharyngeal spaces of the 53 patients, the positive rate of RLN metastasis was significantly higher detected by CT and MRI than by PET-CT (39.6% and 45.3% vs. 20.8%, P<0.01), but the difference between CT and MRI was not significant (P>0.05). CT detected 27 cases of RLN metastasis with the maximum diameter of 0.4-0.9 cm, MRI detected 31 cases, and PET-CT only detected 5 cases. Especially, MRI detected 7 cases of RLN metastasis with the maximum diameter of < or =0.5 cm, CT detected 4 cases, but PET-CT detected none. CT detected 12 cases of RLN metastasis with the maximum diameter of > or =1.0 cm, MRI detected 14 cases, and PET-CT detected 13 cases. All patients were followed-up after treatment. One case of RLN metastasis with necrosis and the maximum diameter of 1.0 cm, and 1 case with the maximum diameter of 1.5 cm were eliminated within 6 months after treatment; the rest were eliminated within 3 months. CONCLUSIONS: In detecting RLN metastasis in NPC, MRI has no obvious advantage over CT, while PET-CT is markedly inferior to CT and MRI, especially in detecting the cases with the maximum diameter of <1.0 cm. Furthermore, the metastatic RLNs with necrosis or the maximum diameter of < or =5 mm can't be detected by PET-CT. Setting the maximum diameter of > or =4 mm as a diagnosis criterion of RLN metastasis for CT or MRI is reasonable and feasible.

About this research paper

What this paper is about

BACKGROUND & OBJECTIVE: At present, the detection of retropharyngeal lymph node (RLN) metastasis in nasopharyngeal carcinoma (NPC) mainly depends on imaging, but the diagnosis criteria are controversial. Recently, the 18F-fluoro-2-deoxy-D-glucose positron emission tomography ((18)FDG-PET-CT) has been widely applied in diagnosing cancer. This study was to evaluate CT, MRI, and (18)FDG-PET-CT in detecting RLN metastasis of NPC, and explore the imaging diagnosis criteria. METHODS: From Dec. 2003 to Aug. 2005, 53 consecutive patients with NPC treated in Cancer Center of Sun Yat-sen University were enrolled. Contrast enhanced CT, MRI, and (18)FDG-PET-CT were performed on bilateral RLNs of the patients within 10 days before treatment. The diagnosis criteria of RLN metastasis for CT and MRI included single node with maximum diameter of > or =4 mm, and the presence of central necrosis or ringed enhancement; the criteria for (18)FDG-PET-CT included abnormal accumulation of irradiation in the RLN with the standard uptake value (SUV) of > or =2.5. Considering the response of RLN to clinical treatment, the differences of CT, MRI, and PET-CT in detecting RLN metastasis were compared. RESULTS: Among the 106 intropharyngeal spaces of the 53 patients, the positive rate of RLN metastasis was significantly higher detected by CT and MRI than by PET-CT (39.6% and 45.3% vs. 20.8%, P<0.01), but the difference between CT and MRI was not significant (P>0.05). CT detected 27 cases of RLN metastasis with the maximum diameter of 0.4-0.9 cm, MRI detected 31 cases, and PET-CT only detected 5 cases. Especially, MRI detected 7 cases of RLN metastasis with the maximum diameter of < or =0.5 cm, CT detected 4 cases, but PET-CT detected none. CT detected 12 cases of RLN metastasis with the maximum diameter of > or =1.0 cm, MRI detected 14 cases, and PET-CT detected 13 cases. All patients were followed-up after treatment. One case of RLN metastasis with necrosis and the maximum diameter of 1.0 cm, and 1 case with the maximum diameter of 1.5 cm were eliminated within 6 months after treatment; the rest were eliminated within 3 months. CONCLUSIONS: In detecting RLN metastasis in NPC, MRI has no obvious advantage over CT, while PET-CT is markedly inferior to CT and MRI, especially in detecting the cases with the maximum diameter of <1.0 cm. Furthermore, the metastatic RLNs with necrosis or the maximum diameter of < or =5 mm can't be detected by PET-CT. Setting the maximum diameter of > or =4 mm as a diagnosis criterion of RLN metastasis for CT or MRI is reasonable and feasible.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND & OBJECTIVE: At present, the detection of retropharyngeal lymph node (RLN) metastasis in nasopharyngeal carcinoma (NPC) mainly depends on imaging, but the diagnosis criteria are controversial. Recently, the 18F-fluoro-2-deoxy-D-glucose positron emission tomography ((18)FDG-PET-CT) has been widely applied in diagnosing cancer. This study was to evaluate CT, MRI, and (18)FDG-PET-CT in detecting RLN metastasis of NPC, and explore the imaging diagnosis criteria. METHODS: From Dec. 2003 to Aug. 2005, 53 consecutive patients with NPC treated in Cancer Center of Sun Yat-sen University were enrolled. Contrast enhanced CT, MRI, and (18)FDG-PET-CT were performed on bilateral RLNs of the patients within 10 days before treatment. The diagnosis criteria of RLN metastasis for CT and MRI included single node with maximum diameter of > or =4 mm, and the presence of central necrosis or ringed enhancement; the criteria for (18)FDG-PET-CT included abnormal accumulation of irradiation in the RLN with the standard uptake value (SUV) of > or =2.5. Considering the response of RLN to clinical treatment, the differences of CT, MRI, and PET-CT in detecting RLN metastasis were compared. RESULTS: Among the 106 intropharyngeal spaces of the 53 patients, the positive rate of RLN metastasis was significantly higher detected by CT and MRI than by PET-CT (39.6% and 45.3% vs. 20.8%, P<0.01), but the difference between CT and MRI was not significant (P>0.05). CT detected 27 cases of RLN metastasis with the maximum diameter of 0.4-0.9 cm, MRI detected 31 cases, and PET-CT only detected 5 cases. Especially, MRI detected 7 cases of RLN metastasis with the maximum diameter of < or =0.5 cm, CT detected 4 cases, but PET-CT detected none. CT detected 12 cases of RLN metastasis with the maximum diameter of > or =1.0 cm, MRI detected 14 cases, and PET-CT detected 13 cases. All patients were followed-up after treatment. One case of RLN metastasis with necrosis and the maximum diameter of 1.0 cm, and 1 case with the maximum diameter of 1.5 cm were eliminated within 6 months after treatment; the rest were eliminated within 3 months. CONCLUSIONS: In detecting RLN metastasis in NPC, MRI has no obvious advantage over CT, while PET-CT is markedly inferior to CT and MRI, especially in detecting the cases with the maximum diameter of <1.0 cm. Furthermore, the metastatic RLNs with necrosis or the maximum diameter of < or =5 mm can't be detected by PET-CT. Setting the maximum diameter of > or =4 mm as a diagnosis criterion of RLN metastasis for CT or MRI is reasonable and feasible.

Key concepts: Medicine, Nasopharyngeal carcinoma, Positron emission tomography, Radiology, Metastasis, Magnetic resonance imaging, Nuclear medicine, Lymph node

Related papers

Back to paper searchBrowse research topicsOriginal source
[Evaluation of CT, MRI and PET-CT in detecting retropharyngeal lymph node metastasis in nasopharyngeal carcinoma]. — Research Paper | ScholarLens