2008•Power System TechnologyRequires access

Influence of AC Transmission Lines on Parallelly Erected UHVDC Transmission Lines and Suppression Measures

WU Ya-ni

Open publisher page 4 citations

Abstract

With unceasingly increasing of electric power requirement and the shortage of corridor resource for transmission lines, in some regions the situation that the UHVDC lines are parallelly erected with UHVAC lines or the corridor is common-used.According to the main circuit parameters of UHVDC project from Xiangjiaba to Nanhui and the data of 1000kV AC transmission line being planned, the model for simulation of UHVAC/UHVDC transmission lines is built by Electro-Magnetic Transient in DC System (EMTDC) program.The power frequency voltages and currents induced in UHVDC lines under different parallel erection lengths and different adjacent distances are calculated.The relation between DC bias current at valve side of converter transformer and power frequency induced current in UHVDC lines is researched;and the corresponding calculation results are given.Several suggestions on the parallel length between UHVAC and UHVDC lines, their adjacent distance and the measure to suppress the DC bias current at valve side of converter transformer are put forward.

About this research paper

What this paper is about

With unceasingly increasing of electric power requirement and the shortage of corridor resource for transmission lines, in some regions the situation that the UHVDC lines are parallelly erected with UHVAC lines or the corridor is common-used.According to the main circuit parameters of UHVDC project from Xiangjiaba to Nanhui and the data of 1000kV AC transmission line being planned, the model for simulation of UHVAC/UHVDC transmission lines is built by Electro-Magnetic Transient in DC System (EMTDC) program.The power frequency voltages and currents induced in UHVDC lines under different parallel erection lengths and different adjacent distances are calculated.The relation between DC bias current at valve side of converter transformer and power frequency induced current in UHVDC lines is researched;and the corresponding calculation results are given.Several suggestions on the parallel length between UHVAC and UHVDC lines, their adjacent distance and the measure to suppress the DC bias current at valve side of converter transformer are put forward.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

With unceasingly increasing of electric power requirement and the shortage of corridor resource for transmission lines, in some regions the situation that the UHVDC lines are parallelly erected with UHVAC lines or the corridor is common-used.According to the main circuit parameters of UHVDC project from Xiangjiaba to Nanhui and the data of 1000kV AC transmission line being planned, the model for simulation of UHVAC/UHVDC transmission lines is built by Electro-Magnetic Transient in DC System (EMTDC) program.The power frequency voltages and currents induced in UHVDC lines under different parallel erection lengths and different adjacent distances are calculated.The relation between DC bias current at valve side of converter transformer and power frequency induced current in UHVDC lines is researched;and the corresponding calculation results are given.Several suggestions on the parallel length between UHVAC and UHVDC lines, their adjacent distance and the measure to suppress the DC bias current at valve side of converter transformer are put forward.

Key concepts: Electrical engineering, Electric power transmission, Transformer, Direct current, Engineering, Economic shortage, Voltage, Transmission line

Related papers

Back to paper searchBrowse research topicsOriginal source
Influence of AC Transmission Lines on Parallelly Erected UHVDC Transmission Lines and Suppression Measures — Research Paper | ScholarLens