2001JOURNAL OF HUNAN AGRICULTURAL UNIVERSITYRequires access

Simultaneous Determination of Arsenic and Antimony in Soil by Hydride Generation Atomic Fluorescence Spectrometry

Le Liu

Open publisher page 0 citations

Abstract

For a simple and quick simultaneous determination of arsenic and antimony in soil,a soil sample was dissolved by using HNO 3 HCl(1+1) and the method of hydride generation atomic fluorescence spectrometry.The effects of the concentration of acid and reducing agent and interference from common coexisting elements on the determination of As and Sb were tested.The results read as follows:the recovery rates of arsenic and antimony are 95%~101% and 91%~93 8% respectively;the detection limits of arsenic and antimony are 0.36 and 0.41 μg/L.The results are in conformity with the standard value.

About this research paper

What this paper is about

For a simple and quick simultaneous determination of arsenic and antimony in soil,a soil sample was dissolved by using HNO 3 HCl(1+1) and the method of hydride generation atomic fluorescence spectrometry.The effects of the concentration of acid and reducing agent and interference from common coexisting elements on the determination of As and Sb were tested.The results read as follows:the recovery rates of arsenic and antimony are 95%~101% and 91%~93 8% respectively;the detection limits of arsenic and antimony are 0.36 and 0.41 μg/L.The results are in conformity with the standard value.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

For a simple and quick simultaneous determination of arsenic and antimony in soil,a soil sample was dissolved by using HNO 3 HCl(1+1) and the method of hydride generation atomic fluorescence spectrometry.The effects of the concentration of acid and reducing agent and interference from common coexisting elements on the determination of As and Sb were tested.The results read as follows:the recovery rates of arsenic and antimony are 95%~101% and 91%~93 8% respectively;the detection limits of arsenic and antimony are 0.36 and 0.41 μg/L.The results are in conformity with the standard value.

Key concepts: Antimony, Arsenic, Hydride, Chemistry, Detection limit, Fluorescence spectrometry, Mass spectrometry, Environmental chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous Determination of Arsenic and Antimony in Soil by Hydride Generation Atomic Fluorescence Spectrometry — Research Paper | ScholarLens