2012Chinese Journal of Analysis LaboratoryRequires access

Optimization of solid phase extraction conditions of diazepam from human plasma using statistical screening and response surface method

Wenlin Xie

Open publisher page 0 citations

Abstract

Plackett-Burman(P-B) design and Central Composite Design(CCD) were applied to optimize 6 factors for the extraction diazepam by solid phase extraction.The P-B design and its following statistical analysis indicate that the pH,sample speed,eluent dosage were the 3 key factors which significantly influenced recovery of diazepam as the response objective,and a quadratic model was obtained by CCD for the 3 factors by analysis of response surface optimization.Under the optimal extraction conditions,pH 10.20,sample speed of 0.67 mL/min and eluent dosage of 2.60 mL,the recovery of diazepam reached 91.26%.The calibration curves were linear over the concentration range of 0.10~10.00 μg/mL(R20.99) and the lower limit of quantification(LOQ) was 0.07 μg/mL.The intra-and inter-day precision(RSD) were less than 10% and accuracy(RE) was less than±6.0%.

About this research paper

What this paper is about

Plackett-Burman(P-B) design and Central Composite Design(CCD) were applied to optimize 6 factors for the extraction diazepam by solid phase extraction.The P-B design and its following statistical analysis indicate that the pH,sample speed,eluent dosage were the 3 key factors which significantly influenced recovery of diazepam as the response objective,and a quadratic model was obtained by CCD for the 3 factors by analysis of response surface optimization.Under the optimal extraction conditions,pH 10.20,sample speed of 0.67 mL/min and eluent dosage of 2.60 mL,the recovery of diazepam reached 91.26%.The calibration curves were linear over the concentration range of 0.10~10.00 μg/mL(R20.99) and the lower limit of quantification(LOQ) was 0.07 μg/mL.The intra-and inter-day precision(RSD) were less than 10% and accuracy(RE) was less than±6.0%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Plackett-Burman(P-B) design and Central Composite Design(CCD) were applied to optimize 6 factors for the extraction diazepam by solid phase extraction.The P-B design and its following statistical analysis indicate that the pH,sample speed,eluent dosage were the 3 key factors which significantly influenced recovery of diazepam as the response objective,and a quadratic model was obtained by CCD for the 3 factors by analysis of response surface optimization.Under the optimal extraction conditions,pH 10.20,sample speed of 0.67 mL/min and eluent dosage of 2.60 mL,the recovery of diazepam reached 91.26%.The calibration curves were linear over the concentration range of 0.10~10.00 μg/mL(R20.99) and the lower limit of quantification(LOQ) was 0.07 μg/mL.The intra-and inter-day precision(RSD) were less than 10% and accuracy(RE) was less than±6.0%.

Key concepts: Central composite design, Extraction (chemistry), Response surface methodology, Chromatography, Chemistry, Detection limit, Diazepam, Column chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Optimization of solid phase extraction conditions of diazepam from human plasma using statistical screening and response surface method — Research Paper | ScholarLens