2013•Chinese Journal of ChromatographyRequires access

Analysis of emodin and its metabolites based on hollow fiber liquid phase microextraction

Jie TIAN, Xuan Chen, Xiaohong Bai

Open publisher page 12 citations

Abstract

Hollow fiber liquid phase microextraction (HFLPME) coupled with high performance liquid chromatography (HPLC) has been developed to analyze the emodin and its metabolites in plasma and urine samples. The abilities of the absorption and metabolism for the active components in traditional Chinese medicines between the male and female rats were compared, and the biological metabolism and transmutation of the analyte were detailed discussed. Emodin and its metabolites in plasma and urine samples were extracted into n-octanol (acceptor) in hollow fiber. The acceptor phase was dried and dissolved by 50 microL methanol and then analyzed by HPLC. Under the optimal conditions, the linearities of the analytes were all very good in biological samples (r > 0.9960), the detection limits of the analytes were within the ranges of 0.1-3.0 microg/L. The enrichment factors were 12.2 to 26.3. The relative standard deviations for intra-day and inter-day precision were lower than 11.0%. The average recoveries of the analytes in plasma and urine samples were all in the range of 97.9% to 103%. HFLPME-HPLC can eliminate interference from complex biological samples, improve the sensitivity and reduce the detection limit, thus this method is suitable for the determination of trace compounds in complex sample.

About this research paper

What this paper is about

Hollow fiber liquid phase microextraction (HFLPME) coupled with high performance liquid chromatography (HPLC) has been developed to analyze the emodin and its metabolites in plasma and urine samples. The abilities of the absorption and metabolism for the active components in traditional Chinese medicines between the male and female rats were compared, and the biological metabolism and transmutation of the analyte were detailed discussed. Emodin and its metabolites in plasma and urine samples were extracted into n-octanol (acceptor) in hollow fiber. The acceptor phase was dried and dissolved by 50 microL methanol and then analyzed by HPLC. Under the optimal conditions, the linearities of the analytes were all very good in biological samples (r > 0.9960), the detection limits of the analytes were within the ranges of 0.1-3.0 microg/L. The enrichment factors were 12.2 to 26.3. The relative standard deviations for intra-day and inter-day precision were lower than 11.0%. The average recoveries of the analytes in plasma and urine samples were all in the range of 97.9% to 103%. HFLPME-HPLC can eliminate interference from complex biological samples, improve the sensitivity and reduce the detection limit, thus this method is suitable for the determination of trace compounds in complex sample.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Hollow fiber liquid phase microextraction (HFLPME) coupled with high performance liquid chromatography (HPLC) has been developed to analyze the emodin and its metabolites in plasma and urine samples. The abilities of the absorption and metabolism for the active components in traditional Chinese medicines between the male and female rats were compared, and the biological metabolism and transmutation of the analyte were detailed discussed. Emodin and its metabolites in plasma and urine samples were extracted into n-octanol (acceptor) in hollow fiber. The acceptor phase was dried and dissolved by 50 microL methanol and then analyzed by HPLC. Under the optimal conditions, the linearities of the analytes were all very good in biological samples (r > 0.9960), the detection limits of the analytes were within the ranges of 0.1-3.0 microg/L. The enrichment factors were 12.2 to 26.3. The relative standard deviations for intra-day and inter-day precision were lower than 11.0%. The average recoveries of the analytes in plasma and urine samples were all in the range of 97.9% to 103%. HFLPME-HPLC can eliminate interference from complex biological samples, improve the sensitivity and reduce the detection limit, thus this method is suitable for the determination of trace compounds in complex sample.

Key concepts: Chromatography, Analyte, High-performance liquid chromatography, Detection limit, Chemistry, Emodin, Sample preparation, Fiber

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis of emodin and its metabolites based on hollow fiber liquid phase microextraction — Research Paper | ScholarLens