OPTIMIZATION AND APPLICATION OF COORDINATION CONTROL STRATEGY FOR IMPROVING THE AGC PERFORMANCE

Jingqiu Kang

Open publisher page 0 citations

Abstract

The reason for poor quality of coordination control system(CCS) and the failure of achieving the index of automatic generation control(AGC) performance examination was analyzed.Partial dynamic adaptive feedforward technique and primary frequency modulation based AGC control method were adopted to optimize the unit coordination control system.The application of optimized coordination control system on an ultra supercritical 1 000 MW power unit showed that,the unit changed its load at rate of 20 MW/min from 500 MW to 1 000 MW.The dynamic and static deviations of the unit load were both less than 1%.The deviation of main steam pressure was less than 0.4 MPa,and that of the main steam temperature was less than 6 ℃.The deviation of slight-superheat steam temperature was less than 10 ℃,the aggregative indicator of the AGC was improved dramatically.

About this research paper

What this paper is about

The reason for poor quality of coordination control system(CCS) and the failure of achieving the index of automatic generation control(AGC) performance examination was analyzed.Partial dynamic adaptive feedforward technique and primary frequency modulation based AGC control method were adopted to optimize the unit coordination control system.The application of optimized coordination control system on an ultra supercritical 1 000 MW power unit showed that,the unit changed its load at rate of 20 MW/min from 500 MW to 1 000 MW.The dynamic and static deviations of the unit load were both less than 1%.The deviation of main steam pressure was less than 0.4 MPa,and that of the main steam temperature was less than 6 ℃.The deviation of slight-superheat steam temperature was less than 10 ℃,the aggregative indicator of the AGC was improved dramatically.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The reason for poor quality of coordination control system(CCS) and the failure of achieving the index of automatic generation control(AGC) performance examination was analyzed.Partial dynamic adaptive feedforward technique and primary frequency modulation based AGC control method were adopted to optimize the unit coordination control system.The application of optimized coordination control system on an ultra supercritical 1 000 MW power unit showed that,the unit changed its load at rate of 20 MW/min from 500 MW to 1 000 MW.The dynamic and static deviations of the unit load were both less than 1%.The deviation of main steam pressure was less than 0.4 MPa,and that of the main steam temperature was less than 6 ℃.The deviation of slight-superheat steam temperature was less than 10 ℃,the aggregative indicator of the AGC was improved dramatically.

Key concepts: Automatic Generation Control, Feed forward, Supercritical fluid, Unit load, Control theory (sociology), Control system, Frequency deviation, Automatic frequency control