Pointing to the deficiency of the in-situ test measurement of the thermal infrared imager,a set of portable test device of the thermal infrared imager with MRTD has been designed.First,test the MRTD of the thermal infrared imager in-situ.And then,calculate the apparent temperature difference of the target through the model of the atmosphere trasmissivity.At last,through the Johnson criterion,analyze,calculate and obtain the ability of detecting and recognizing the target by the thermal infrared imager.The experiment result shows that the method is exactly feasible and may be used to test the findable distance of all rinds of the thermal infrared imager.

About this research paper

What this paper is about

Pointing to the deficiency of the in-situ test measurement of the thermal infrared imager,a set of portable test device of the thermal infrared imager with MRTD has been designed.First,test the MRTD of the thermal infrared imager in-situ.And then,calculate the apparent temperature difference of the target through the model of the atmosphere trasmissivity.At last,through the Johnson criterion,analyze,calculate and obtain the ability of detecting and recognizing the target by the thermal infrared imager.The experiment result shows that the method is exactly feasible and may be used to test the findable distance of all rinds of the thermal infrared imager.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Pointing to the deficiency of the in-situ test measurement of the thermal infrared imager,a set of portable test device of the thermal infrared imager with MRTD has been designed.First,test the MRTD of the thermal infrared imager in-situ.And then,calculate the apparent temperature difference of the target through the model of the atmosphere trasmissivity.At last,through the Johnson criterion,analyze,calculate and obtain the ability of detecting and recognizing the target by the thermal infrared imager.The experiment result shows that the method is exactly feasible and may be used to test the findable distance of all rinds of the thermal infrared imager.

Key concepts: Infrared, Thermal infrared, Thermal, Remote sensing, Atmosphere (unit), Field (mathematics), Optics, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
Research on the Field Device for Testing Findable Distance of Thermal Infrared Imager — Research Paper | ScholarLens