2012•Mining and Metallurgical EngineeringRequires access

Research on Selective Leaching of Cobalt White Alloy from Weakly Acidic Solution

Xue Sheng-hui

Open publisher page 1 citations

Abstract

Valuable metals were selectively leached from cobalt white alloy by using air as oxidant in diluted hydrochloric acid system.Continuous leaching tests were conducted under the following optimum leaching conditions: at a reaction temperature of 85 ℃,with solid-to-liquid ratio of 1∶10,agitation speed of 1 000 r/min and leaching time of 12 h,with a 15% excess of system acid,an air flux of 4 L/min,and the dosage of additive NL being 4%(relative to cobalt white alloy).Results showed the leaching rate of Co,Cu and Ni reached up to 95.27%,95.14% and 94.28%,respectively.

About this research paper

What this paper is about

Valuable metals were selectively leached from cobalt white alloy by using air as oxidant in diluted hydrochloric acid system.Continuous leaching tests were conducted under the following optimum leaching conditions: at a reaction temperature of 85 ℃,with solid-to-liquid ratio of 1∶10,agitation speed of 1 000 r/min and leaching time of 12 h,with a 15% excess of system acid,an air flux of 4 L/min,and the dosage of additive NL being 4%(relative to cobalt white alloy).Results showed the leaching rate of Co,Cu and Ni reached up to 95.27%,95.14% and 94.28%,respectively.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Valuable metals were selectively leached from cobalt white alloy by using air as oxidant in diluted hydrochloric acid system.Continuous leaching tests were conducted under the following optimum leaching conditions: at a reaction temperature of 85 ℃,with solid-to-liquid ratio of 1∶10,agitation speed of 1 000 r/min and leaching time of 12 h,with a 15% excess of system acid,an air flux of 4 L/min,and the dosage of additive NL being 4%(relative to cobalt white alloy).Results showed the leaching rate of Co,Cu and Ni reached up to 95.27%,95.14% and 94.28%,respectively.

Key concepts: Leaching (pedology), Hydrochloric acid, Cobalt, Alloy, Metallurgy, Selective leaching, Chemistry, Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
Research on Selective Leaching of Cobalt White Alloy from Weakly Acidic Solution — Research Paper | ScholarLens