2008•Clean Coal TechnologyRequires access

The off-design characteristic research of 200MW IGCC system

Xiaoli Chen

Open publisher page 0 citations

Abstract

The mature commercial software Thermoflex was used to simulate the IGCC system.200MW IGCC system was established and material and thermal equilibriums were calculated in the text.The reasons of resulting in IGCC system off-design were analyzed,and the result shows that the mostly reasons of resulting in IGCC system off-design are the varieties of unit load,atmosphere condition and components capability.The characteristic of system off-design aroused by the changes of gas turbine load and atmosphere condition(environment temperature,atmosphere pressure)was calculated and analyzed.The change rules of system efficiency and power,gas turbine efficiency and power,and mostly parameters of steam side in the IGCC system off-design are gained.

About this research paper

What this paper is about

The mature commercial software Thermoflex was used to simulate the IGCC system.200MW IGCC system was established and material and thermal equilibriums were calculated in the text.The reasons of resulting in IGCC system off-design were analyzed,and the result shows that the mostly reasons of resulting in IGCC system off-design are the varieties of unit load,atmosphere condition and components capability.The characteristic of system off-design aroused by the changes of gas turbine load and atmosphere condition(environment temperature,atmosphere pressure)was calculated and analyzed.The change rules of system efficiency and power,gas turbine efficiency and power,and mostly parameters of steam side in the IGCC system off-design are gained.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The mature commercial software Thermoflex was used to simulate the IGCC system.200MW IGCC system was established and material and thermal equilibriums were calculated in the text.The reasons of resulting in IGCC system off-design were analyzed,and the result shows that the mostly reasons of resulting in IGCC system off-design are the varieties of unit load,atmosphere condition and components capability.The characteristic of system off-design aroused by the changes of gas turbine load and atmosphere condition(environment temperature,atmosphere pressure)was calculated and analyzed.The change rules of system efficiency and power,gas turbine efficiency and power,and mostly parameters of steam side in the IGCC system off-design are gained.

Key concepts: Integrated gasification combined cycle, Steam turbine, Atmosphere (unit), Process engineering, Thermal power station, Combined cycle, Engineering, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
The off-design characteristic research of 200MW IGCC system — Research Paper | ScholarLens