Firstly the optimum conditions of experiment were selected.A new determination was established.It was a joint determination,rare earth in the new inoculation was determined by Spectrophotometry,and chromium,manganese,silicon in the new inoculation were determined by volumetric determination.A blue purple colored coordination complex of rare earth and chlorophosphonazo Ⅲ was formed under the certain acidity.Absorption maximum of the complex was found at the wavelength of 660nm,Lambert-Beer's law was kept in the range within 20 g of rare earth per 50mL of solution.Linear correlation coefficient r=0.999 6.Chromium and Manganese in the solution were titrated with standard of Fe(NH4)2(SO4)2,the indicator was N-phenylanthranilic acid.This determination is easy to operate,higher accuracy,it can meet the needs of the ordinary test.The results of the determinations were obtained by standard addition method,giving the values of recovery were more than 98%.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Firstly the optimum conditions of experiment were selected.A new determination was established.It was a joint determination,rare earth in the new inoculation was determined by Spectrophotometry,and chromium,manganese,silicon in the new inoculation were determined by volumetric determination.A blue purple colored coordination complex of rare earth and chlorophosphonazo Ⅲ was formed under the certain acidity.Absorption maximum of the complex was found at the wavelength of 660nm,Lambert-Beer's law was kept in the range within 20 g of rare earth per 50mL of solution.Linear correlation coefficient r=0.999 6.Chromium and Manganese in the solution were titrated with standard of Fe(NH4)2(SO4)2,the indicator was N-phenylanthranilic acid.This determination is easy to operate,higher accuracy,it can meet the needs of the ordinary test.The results of the determinations were obtained by standard addition method,giving the values of recovery were more than 98%.
Key concepts: Manganese, Chromium, Silicon, Rare earth, Atomic absorption spectroscopy, Chemistry, Spectrophotometry, Earth (classical element)