2011Zhongguo yaofangRequires access

Content Determination of Geraniol in Cymbopogon citratus by GC

Xiao Zhi-xing, Feng Jing-yi

Open publisher page 0 citations

Abstract

OBJECTIVE:To establish the method for the content determination of geraniol in Cymbopogon citratus.METHODS:Geraniol was extracted from C.citratus by ultrasonic extraction.The content of geraniol was determined by GC.Chromatographic column was Agilent Technologies DB-WAX(30 m×0.25 mm×0.25 μm) with PEG-20M as solid phase.The column temperature was 130 ℃,injector temperature was 230 ℃ and temperature of detector was 250 ℃.The flow rated of N2(carrier gas) was 1.0 mL·min-1 kPa.The flow rated of H2(fuel gas) was 40 mL·min-1 and that of air(assistant fuel gas) was 400 mL·min-1.RESULTS:The linear range of geraniol was 0.015 3~0.107 1 μg(r=0.997 3) with an average recovery of 97.8%(RSD=1.68%,n=6).CONCLUSION:This method is simple,rapid and accurate,with good reproducibility.It can be used for quality control of C.citratus.

About this research paper

What this paper is about

OBJECTIVE:To establish the method for the content determination of geraniol in Cymbopogon citratus.METHODS:Geraniol was extracted from C.citratus by ultrasonic extraction.The content of geraniol was determined by GC.Chromatographic column was Agilent Technologies DB-WAX(30 m×0.25 mm×0.25 μm) with PEG-20M as solid phase.The column temperature was 130 ℃,injector temperature was 230 ℃ and temperature of detector was 250 ℃.The flow rated of N2(carrier gas) was 1.0 mL·min-1 kPa.The flow rated of H2(fuel gas) was 40 mL·min-1 and that of air(assistant fuel gas) was 400 mL·min-1.RESULTS:The linear range of geraniol was 0.015 3~0.107 1 μg(r=0.997 3) with an average recovery of 97.8%(RSD=1.68%,n=6).CONCLUSION:This method is simple,rapid and accurate,with good reproducibility.It can be used for quality control of C.citratus.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE:To establish the method for the content determination of geraniol in Cymbopogon citratus.METHODS:Geraniol was extracted from C.citratus by ultrasonic extraction.The content of geraniol was determined by GC.Chromatographic column was Agilent Technologies DB-WAX(30 m×0.25 mm×0.25 μm) with PEG-20M as solid phase.The column temperature was 130 ℃,injector temperature was 230 ℃ and temperature of detector was 250 ℃.The flow rated of N2(carrier gas) was 1.0 mL·min-1 kPa.The flow rated of H2(fuel gas) was 40 mL·min-1 and that of air(assistant fuel gas) was 400 mL·min-1.RESULTS:The linear range of geraniol was 0.015 3~0.107 1 μg(r=0.997 3) with an average recovery of 97.8%(RSD=1.68%,n=6).CONCLUSION:This method is simple,rapid and accurate,with good reproducibility.It can be used for quality control of C.citratus.

Key concepts: Cymbopogon citratus, Geraniol, Chromatography, Chemistry, Citral, Reproducibility, Content determination, Essential oil

Related papers

Back to paper searchBrowse research topicsOriginal source
Content Determination of Geraniol in Cymbopogon citratus by GC — Research Paper | ScholarLens