2003石材Requires access

Simultaneous Determination of Harmful Elements in Granite with Microwave Digestion by ICP - AES

Liu Hong-wei

Open publisher page 0 citations

Abstract

The essay develops a new method of microwave degestion with a sample of ICP - AES simultanuously determining Pb, Cd, Cr and As. Under the optinum condition , the detection limits of Pb, Cd, Cr and As are 0. 0008, 0. 0007, 0. 0018, 0. 0012(μg ·L - lrespectively). The recoveries of the method are 93.4% - 102. 5%, RSD1. 3% -3.6%. This method is accurate, quick-acquired and convenient.Ilt is used in the determination of granite with the result is satisfactory.

About this research paper

What this paper is about

The essay develops a new method of microwave degestion with a sample of ICP - AES simultanuously determining Pb, Cd, Cr and As. Under the optinum condition , the detection limits of Pb, Cd, Cr and As are 0. 0008, 0. 0007, 0. 0018, 0. 0012(μg ·L - lrespectively). The recoveries of the method are 93.4% - 102. 5%, RSD1. 3% -3.6%. This method is accurate, quick-acquired and convenient.Ilt is used in the determination of granite with the result is satisfactory.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The essay develops a new method of microwave degestion with a sample of ICP - AES simultanuously determining Pb, Cd, Cr and As. Under the optinum condition , the detection limits of Pb, Cd, Cr and As are 0. 0008, 0. 0007, 0. 0018, 0. 0012(μg ·L - lrespectively). The recoveries of the method are 93.4% - 102. 5%, RSD1. 3% -3.6%. This method is accurate, quick-acquired and convenient.Ilt is used in the determination of granite with the result is satisfactory.

Key concepts: Inductively coupled plasma atomic emission spectroscopy, Microwave digestion, Chemistry, Microwave, Detection limit, Analytical Chemistry (journal), Mineralogy, Environmental chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous Determination of Harmful Elements in Granite with Microwave Digestion by ICP - AES — Research Paper | ScholarLens