2010Radiologic PracticeRequires access

Comparative study of the value of color Doppler ultrasonography and multi-slice CT angiography in the stent-assisted angioplasty of carotid artery stenosis

Linhong Zhang

Open publisher page 0 citations

Abstract

Objective:To evaluate the value of multi-slice CT angiography(MSCTA) and ultrasonography color Doppler flow imaging(CDFI) in the stent-assisted angioplasty of carotid artery stenosis(CAS).Methods:The imaging data of MSCTA and CDFI before and after stent-assisted angioplasty of CAS in 36 patients were analyzed retrospectively.Digital subtracted angiography(DSA) was used as the golden standard.The accuracy of evaluating the degree of CAS and the density of arterio-sclerotic plaque by CDFI and MSCTA as well as the value of these two techniques in stent-assisted angioplasty of CAS were compared.Results:The sensitivity of CDFI and MSCTA in the diagnosis of CAS was 90.9% and 92.8% respectively,the specificity was 95.6% and 95.7% respectively,the accuracy was 92.4% and 93.8% respectively,negative predictive value was 82.7% and 86.5% respectively,positive predictive value was 97.8% and 97.8% respectively.The coincidence rate of analyzing carotid atherosclerosis plaque by CDFI and MSCTA was 86.9%.Conclusion:For the stent-assisted angioplasty of CAS,CDFI could be used for screening of carotid artery lesion,evaluation of treatment effect and follow up.MSCTA is superior in displaying high position bifurcation,intra-cranial segment of internal carotid artery and the variation of carotid artery pathway.The accuracy of diagnosis could be improved with CDFI in combination with MSCTA.

About this research paper

What this paper is about

Objective:To evaluate the value of multi-slice CT angiography(MSCTA) and ultrasonography color Doppler flow imaging(CDFI) in the stent-assisted angioplasty of carotid artery stenosis(CAS).Methods:The imaging data of MSCTA and CDFI before and after stent-assisted angioplasty of CAS in 36 patients were analyzed retrospectively.Digital subtracted angiography(DSA) was used as the golden standard.The accuracy of evaluating the degree of CAS and the density of arterio-sclerotic plaque by CDFI and MSCTA as well as the value of these two techniques in stent-assisted angioplasty of CAS were compared.Results:The sensitivity of CDFI and MSCTA in the diagnosis of CAS was 90.9% and 92.8% respectively,the specificity was 95.6% and 95.7% respectively,the accuracy was 92.4% and 93.8% respectively,negative predictive value was 82.7% and 86.5% respectively,positive predictive value was 97.8% and 97.8% respectively.The coincidence rate of analyzing carotid atherosclerosis plaque by CDFI and MSCTA was 86.9%.Conclusion:For the stent-assisted angioplasty of CAS,CDFI could be used for screening of carotid artery lesion,evaluation of treatment effect and follow up.MSCTA is superior in displaying high position bifurcation,intra-cranial segment of internal carotid artery and the variation of carotid artery pathway.The accuracy of diagnosis could be improved with CDFI in combination with MSCTA.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To evaluate the value of multi-slice CT angiography(MSCTA) and ultrasonography color Doppler flow imaging(CDFI) in the stent-assisted angioplasty of carotid artery stenosis(CAS).Methods:The imaging data of MSCTA and CDFI before and after stent-assisted angioplasty of CAS in 36 patients were analyzed retrospectively.Digital subtracted angiography(DSA) was used as the golden standard.The accuracy of evaluating the degree of CAS and the density of arterio-sclerotic plaque by CDFI and MSCTA as well as the value of these two techniques in stent-assisted angioplasty of CAS were compared.Results:The sensitivity of CDFI and MSCTA in the diagnosis of CAS was 90.9% and 92.8% respectively,the specificity was 95.6% and 95.7% respectively,the accuracy was 92.4% and 93.8% respectively,negative predictive value was 82.7% and 86.5% respectively,positive predictive value was 97.8% and 97.8% respectively.The coincidence rate of analyzing carotid atherosclerosis plaque by CDFI and MSCTA was 86.9%.Conclusion:For the stent-assisted angioplasty of CAS,CDFI could be used for screening of carotid artery lesion,evaluation of treatment effect and follow up.MSCTA is superior in displaying high position bifurcation,intra-cranial segment of internal carotid artery and the variation of carotid artery pathway.The accuracy of diagnosis could be improved with CDFI in combination with MSCTA.

Key concepts: Medicine, Radiology, Angioplasty, Stenosis, Angiography, Stent, Carotid arteries, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparative study of the value of color Doppler ultrasonography and multi-slice CT angiography in the stent-assisted angioplasty of carotid artery stenosis — Research Paper | ScholarLens