[APPLICATION OF THIN-LAYER CHROMATOGRAPHY USING SILICA GEL WITHOUT BINDER TO THE IDENTIFICATION OF STEROIDS].
Chiang Th, Yao Tc
Abstract
Chiang Th, Yao Tc
Abstract
The thin-layer chromatography using silica gel without binder for rapid identification of steroids is described. The advantage of the present method over that using alumina thin-layer without binder is its precise resolving power, and in comparison with the thin-layer of silica gel with binder, it possesses the additional advantages of simplicity and speed. The spots on the thin-layer can easily be detected with the reagent by impregnating one side of the thin-layer perpendicular to the developing direction. The spots or zones can also be de- tected by impregnation with only a simple solvent in which the compounds to be iden- tified are insoluble. The specifications and reagents used in the present investigation are as follows: Silica gel for chromatography: 18-250 mesh and below 250 mesh; grade Ⅰ/Ⅱ. Dimensions of thin-layer; 120×60×0.6mm. Solvents for development: benzene-Ethyl acetate (7:3, 5:5, 4:6, 1:9). Reagents for detection: (1) aqueous solution of 3% phosphomolybdic acid; (2) aqueous solution of 2,4-dinitrophenylhydrazine. A series of 20 steroid compounts are chromatographed on the thin layer of silica gel without binder.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The thin-layer chromatography using silica gel without binder for rapid identification of steroids is described. The advantage of the present method over that using alumina thin-layer without binder is its precise resolving power, and in comparison with the thin-layer of silica gel with binder, it possesses the additional advantages of simplicity and speed. The spots on the thin-layer can easily be detected with the reagent by impregnating one side of the thin-layer perpendicular to the developing direction. The spots or zones can also be de- tected by impregnation with only a simple solvent in which the compounds to be iden- tified are insoluble. The specifications and reagents used in the present investigation are as follows: Silica gel for chromatography: 18-250 mesh and below 250 mesh; grade Ⅰ/Ⅱ. Dimensions of thin-layer; 120×60×0.6mm. Solvents for development: benzene-Ethyl acetate (7:3, 5:5, 4:6, 1:9). Reagents for detection: (1) aqueous solution of 3% phosphomolybdic acid; (2) aqueous solution of 2,4-dinitrophenylhydrazine. A series of 20 steroid compounts are chromatographed on the thin layer of silica gel without binder.
Key concepts: Silica gel, Reagent, Thin-layer chromatography, Phosphomolybdic acid, Chromatography, Layer (electronics), Aqueous solution, Chemistry