2011Tobacco Science & TechnologyRequires access

Determination of Acidity of Triacetin with Automatic Potentiometric Titration

Zhou Pei-Chen, Liu Zechun, Huang Huafa, Feng Zhang, Zhang Ding-Fang, Liu Jiang-sheng, Lai Wei-Ling

Open publisher page 0 citations

Abstract

In order to get rid of the disadvantages of conventional acid-base titration in determining the acidity of triacetin,such as inconvenience in endpoint differentiation and high relative standard deviation,automatic potentiometric titration was investigated.The results showed that the recoveries of the method ranged from 99.5% to 103.3% with the relative standard deviation of 0.774% and the limit of quantitation of 0.00175%.It proved that the acidity of triacetin could be rapidly and accurately determined with automatic potentiometric titration.

About this research paper

What this paper is about

In order to get rid of the disadvantages of conventional acid-base titration in determining the acidity of triacetin,such as inconvenience in endpoint differentiation and high relative standard deviation,automatic potentiometric titration was investigated.The results showed that the recoveries of the method ranged from 99.5% to 103.3% with the relative standard deviation of 0.774% and the limit of quantitation of 0.00175%.It proved that the acidity of triacetin could be rapidly and accurately determined with automatic potentiometric titration.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In order to get rid of the disadvantages of conventional acid-base titration in determining the acidity of triacetin,such as inconvenience in endpoint differentiation and high relative standard deviation,automatic potentiometric titration was investigated.The results showed that the recoveries of the method ranged from 99.5% to 103.3% with the relative standard deviation of 0.774% and the limit of quantitation of 0.00175%.It proved that the acidity of triacetin could be rapidly and accurately determined with automatic potentiometric titration.

Key concepts: Potentiometric titration, Triacetin, Titration, Relative standard deviation, Chemistry, Chromatography, Gran plot, Detection limit