Determination of Perchlorate in Surface Water by High Performance Liquid Chromatography-Electrospray Ion Source-Tandem Mass Spectrometry
Xie Yong-hon
Abstract
Xie Yong-hon
Abstract
A method was developed for determination of perchlorate in surface water based on high performance liquid chromatography-electrospray ion sourcetandem mass spectrometry( HPLC-ESI-MS / MS). The anion exchange column of Dionex IonPac AG20 was used as the analytical column with the weakly alkaline mobile phase of 0. 056% ammonia /5 mmol / L Ammonium acetate and the flow rate of 1. 0 mL / min.-ESI MS / MS was used as the detector and the perhclorate was detected under multiple reaction monitoring( MRM) mode. The detection limit of the developed method was 0. 043 μg / L and the linear range was 0. 2-50 μg / L with the linear correlation coefficient of 0. 999 4,the relative standard deviation for about 2,6,30 μg / L sample were 2. 47%,4. 55%,0. 49%,respectively. Content recovery percentages ranging from 80% to 109% were obtained and the analysis results were of agreement with that analyzed by US EPA method314. 0.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A method was developed for determination of perchlorate in surface water based on high performance liquid chromatography-electrospray ion sourcetandem mass spectrometry( HPLC-ESI-MS / MS). The anion exchange column of Dionex IonPac AG20 was used as the analytical column with the weakly alkaline mobile phase of 0. 056% ammonia /5 mmol / L Ammonium acetate and the flow rate of 1. 0 mL / min.-ESI MS / MS was used as the detector and the perhclorate was detected under multiple reaction monitoring( MRM) mode. The detection limit of the developed method was 0. 043 μg / L and the linear range was 0. 2-50 μg / L with the linear correlation coefficient of 0. 999 4,the relative standard deviation for about 2,6,30 μg / L sample were 2. 47%,4. 55%,0. 49%,respectively. Content recovery percentages ranging from 80% to 109% were obtained and the analysis results were of agreement with that analyzed by US EPA method314. 0.
Key concepts: Chemistry, Chromatography, Detection limit, Electrospray, Analytical Chemistry (journal), Selected reaction monitoring, Mass spectrometry, Ion chromatography