Determination of ~(234)U/~(238)U,~(230)Th/~(232)Th,~(228)Ra/~(226)Ra Ratios in Uranium Ores by High-resolution Inductively Coupled Plasma-Mass Spectrometry
Tan Jing
Abstract
Tan Jing
Abstract
Uranium ore samples are decomposed with HF-HNO3-HCl in sealed vessels.Anion exchange resin is used to separate U from Th and Ra,Th from Ra.Sr-specific resin is applied to separate Ra from Ba and other elements.Purified U,Th and Ra(solutions) are used for measurement of 234U/238U,230Th/232Th and 228Ra/226Ra by HR-ICPMS.The precision of the isotopic ratio measurements for 234U/238U,230Th/232Th and 228Ra/226Ra depends on their isotopic ratios and the concentration of relative nuclides.For a 10 ng/mL natural uranium solution,the isotopic ratio measurement precision for 234U/238U is better than 1.2%RSD,for a solution with 0.6 ng/mL of 230Th and nearly equal concentration of 230Th and 232Th,the measurement precision for 230Th/232Th is 1.2%RSD and for a solution with 0.48 pg/mL of 228Ra and nearly equal concentration of 228Ra and 226Ra,the measurement precision for 228Ra/226Ra is 4.0%RSD.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Uranium ore samples are decomposed with HF-HNO3-HCl in sealed vessels.Anion exchange resin is used to separate U from Th and Ra,Th from Ra.Sr-specific resin is applied to separate Ra from Ba and other elements.Purified U,Th and Ra(solutions) are used for measurement of 234U/238U,230Th/232Th and 228Ra/226Ra by HR-ICPMS.The precision of the isotopic ratio measurements for 234U/238U,230Th/232Th and 228Ra/226Ra depends on their isotopic ratios and the concentration of relative nuclides.For a 10 ng/mL natural uranium solution,the isotopic ratio measurement precision for 234U/238U is better than 1.2%RSD,for a solution with 0.6 ng/mL of 230Th and nearly equal concentration of 230Th and 232Th,the measurement precision for 230Th/232Th is 1.2%RSD and for a solution with 0.48 pg/mL of 228Ra and nearly equal concentration of 228Ra and 226Ra,the measurement precision for 228Ra/226Ra is 4.0%RSD.
Key concepts: Uranium, Chemistry, Isotopic ratio, Radiochemistry, Nuclide, Inductively coupled plasma mass spectrometry, Isotope, Analytical Chemistry (journal)