2010•Oil Field EquipmentRequires access

Study on Throat Parameters for Partial Emission Pump with Conventional Speed

Xiancheng Song

Open publisher page 0 citations

Abstract

CFD technology was used in study of the partial emission pump,and changes 5 kind of throat parameters at the same time.The paper conversely calculates the result of numerical simulation and the test and discusses the impact of the changes of the throat parameters to the partial emission pump.The research show that When the throat diameter under 0.8Dd,head and efficiency decreases rapidly.When the throat diameter above 1.4Dd,head and efficiency a little higher than that in design conditions.The distribution of static pressure and total pressure is reasonable in the partial emission pump.With the increasing of throat parameters,high-lift coefficient increases,but the flow coefficient reduce.

About this research paper

What this paper is about

CFD technology was used in study of the partial emission pump,and changes 5 kind of throat parameters at the same time.The paper conversely calculates the result of numerical simulation and the test and discusses the impact of the changes of the throat parameters to the partial emission pump.The research show that When the throat diameter under 0.8Dd,head and efficiency decreases rapidly.When the throat diameter above 1.4Dd,head and efficiency a little higher than that in design conditions.The distribution of static pressure and total pressure is reasonable in the partial emission pump.With the increasing of throat parameters,high-lift coefficient increases,but the flow coefficient reduce.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

CFD technology was used in study of the partial emission pump,and changes 5 kind of throat parameters at the same time.The paper conversely calculates the result of numerical simulation and the test and discusses the impact of the changes of the throat parameters to the partial emission pump.The research show that When the throat diameter under 0.8Dd,head and efficiency decreases rapidly.When the throat diameter above 1.4Dd,head and efficiency a little higher than that in design conditions.The distribution of static pressure and total pressure is reasonable in the partial emission pump.With the increasing of throat parameters,high-lift coefficient increases,but the flow coefficient reduce.

Key concepts: Throat, Lift (data mining), Mechanics, Computational fluid dynamics, Partial pressure, Pressure head, Head (geology), Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source