2015•Guangzhou Chemical IndustryRequires access

Determination of Copper in Silver Copper Alloys by ICP-AES

Liu Shou-qion

Open publisher page 0 citations

Abstract

The content of copper in silver copper alloys was determined by inductively coupled plasma atomic emission spectrometry(ICP-AES). Accurately measured 0. 1000 g copper and silver alloy samples in erlenmeyer flask,added 5 m L nitric acid(P = 1. 42 g·m L-1),after waiting for the completion of the reaction,added a little water,and a certain concentration of hydrochloric acid solution,silver precipitation precipitated,after filter and volume,selected wavelength Cu327. 396 nm,the copper content was determinate according to rated working conditions on the machine.The detection limit was 0. 01 mg / L,the precision(RSD) control was less than 1. 0%,recovery rate was 97% ~ 103%,five homemade samples were measured(n = 10) and the results conformed to the requirements.

About this research paper

What this paper is about

The content of copper in silver copper alloys was determined by inductively coupled plasma atomic emission spectrometry(ICP-AES). Accurately measured 0. 1000 g copper and silver alloy samples in erlenmeyer flask,added 5 m L nitric acid(P = 1. 42 g·m L-1),after waiting for the completion of the reaction,added a little water,and a certain concentration of hydrochloric acid solution,silver precipitation precipitated,after filter and volume,selected wavelength Cu327. 396 nm,the copper content was determinate according to rated working conditions on the machine.The detection limit was 0. 01 mg / L,the precision(RSD) control was less than 1. 0%,recovery rate was 97% ~ 103%,five homemade samples were measured(n = 10) and the results conformed to the requirements.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The content of copper in silver copper alloys was determined by inductively coupled plasma atomic emission spectrometry(ICP-AES). Accurately measured 0. 1000 g copper and silver alloy samples in erlenmeyer flask,added 5 m L nitric acid(P = 1. 42 g·m L-1),after waiting for the completion of the reaction,added a little water,and a certain concentration of hydrochloric acid solution,silver precipitation precipitated,after filter and volume,selected wavelength Cu327. 396 nm,the copper content was determinate according to rated working conditions on the machine.The detection limit was 0. 01 mg / L,the precision(RSD) control was less than 1. 0%,recovery rate was 97% ~ 103%,five homemade samples were measured(n = 10) and the results conformed to the requirements.

Key concepts: Copper, Erlenmeyer flask, Nitric acid, Inductively coupled plasma, Inductively coupled plasma atomic emission spectroscopy, Detection limit, Chemistry, Hydrochloric acid

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Copper in Silver Copper Alloys by ICP-AES — Research Paper | ScholarLens