2008PubMedRequires access

[Determination of melamine residue in plant origin protein powders using high performance liquid chromatography-diode array detection and high performance liquid chromatography-electrospray ionization tandem mass spectrometry].

Tao Ding, Jinzhong Xu, Jianzhong Li, Chongyu Shen, Bin Wu, Huilan Chen, Shujuan Li

Open publisher page 20 citations

Abstract

A method for the determination of melamine residue in plant origin protein powders was developed using high performance liquid chromatography-diode array detection (HPLC-DAD) and HPLC-electrospray ionization tandem mass spectrometry (ESI-MS/MS). HPL-DAD was used in preliminary screening of the samples for melamine, and HPLC-MS/MS was used in the confirmatory of melamine. Trichloroacetic acid solution was used to precipitate proteins and to dissociate the target analyte from the sample matrix. The supernatant was cleaned up with strong cation exchange column for HPLC-MS/MS. The HPLC-DAD separation was carried out on a C18 column (250 mm x 4.6 mm, 5 microm) with 0.01 mol/L sodium n-heptanesulfate (pH adjusted to 4.5 with citric acid)-acetonitrile (90:10, v/v) as mobile phase at a flow rate of 1.0 mL/min, and detected at 240 nm. HPLC-MS/MS was performed in selected ion monitoring mode with trichloroacetic acid solution as ion pair reagent. The limits of detection were 10 mg/kg and 0.5 mg/kg for HPLC-DAD and HPLC-MS/MS, respectively. The mean recoveries were 76%-88% for HPLC-DAD and 72%-82% (matrix match calibration curve) for HPLC-MS/MS and the relative standard deviations were 3.4%-6.4% for both HPLC-DAD and HPLC-MS/MS.

About this research paper

What this paper is about

A method for the determination of melamine residue in plant origin protein powders was developed using high performance liquid chromatography-diode array detection (HPLC-DAD) and HPLC-electrospray ionization tandem mass spectrometry (ESI-MS/MS). HPL-DAD was used in preliminary screening of the samples for melamine, and HPLC-MS/MS was used in the confirmatory of melamine. Trichloroacetic acid solution was used to precipitate proteins and to dissociate the target analyte from the sample matrix. The supernatant was cleaned up with strong cation exchange column for HPLC-MS/MS. The HPLC-DAD separation was carried out on a C18 column (250 mm x 4.6 mm, 5 microm) with 0.01 mol/L sodium n-heptanesulfate (pH adjusted to 4.5 with citric acid)-acetonitrile (90:10, v/v) as mobile phase at a flow rate of 1.0 mL/min, and detected at 240 nm. HPLC-MS/MS was performed in selected ion monitoring mode with trichloroacetic acid solution as ion pair reagent. The limits of detection were 10 mg/kg and 0.5 mg/kg for HPLC-DAD and HPLC-MS/MS, respectively. The mean recoveries were 76%-88% for HPLC-DAD and 72%-82% (matrix match calibration curve) for HPLC-MS/MS and the relative standard deviations were 3.4%-6.4% for both HPLC-DAD and HPLC-MS/MS.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for the determination of melamine residue in plant origin protein powders was developed using high performance liquid chromatography-diode array detection (HPLC-DAD) and HPLC-electrospray ionization tandem mass spectrometry (ESI-MS/MS). HPL-DAD was used in preliminary screening of the samples for melamine, and HPLC-MS/MS was used in the confirmatory of melamine. Trichloroacetic acid solution was used to precipitate proteins and to dissociate the target analyte from the sample matrix. The supernatant was cleaned up with strong cation exchange column for HPLC-MS/MS. The HPLC-DAD separation was carried out on a C18 column (250 mm x 4.6 mm, 5 microm) with 0.01 mol/L sodium n-heptanesulfate (pH adjusted to 4.5 with citric acid)-acetonitrile (90:10, v/v) as mobile phase at a flow rate of 1.0 mL/min, and detected at 240 nm. HPLC-MS/MS was performed in selected ion monitoring mode with trichloroacetic acid solution as ion pair reagent. The limits of detection were 10 mg/kg and 0.5 mg/kg for HPLC-DAD and HPLC-MS/MS, respectively. The mean recoveries were 76%-88% for HPLC-DAD and 72%-82% (matrix match calibration curve) for HPLC-MS/MS and the relative standard deviations were 3.4%-6.4% for both HPLC-DAD and HPLC-MS/MS.

Key concepts: Chemistry, Chromatography, High-performance liquid chromatography, Mass spectrometry, Electrospray ionization, Tandem mass spectrometry, Electrospray, Melamine

Related papers

Back to paper searchBrowse research topicsOriginal source
[Determination of melamine residue in plant origin protein powders using high performance liquid chromatography-diode array detection and high performance liquid chromatography-electrospray ionization tandem mass spectrometry]. — Research Paper | ScholarLens