2015Anhui nongye kexueRequires access

Determination of 8 Heavy Metals in Vegetables by Inductively Coupled Plasma Mass Spectrometry

Le Yang

Open publisher page 0 citations

Abstract

[Objective]A method for determination of heavy metals in vegetables by inductively coupled plasma mass spectrometry( ICP-MS)is proposed. [Method] The samples were digested by a mixed reagent of HNO3- H2O2 sealed vessels. Rh and Re were selected as internal standard to compensate the analytical signal drift. The method was verified by national standard substance elements. [Result] It is shown that the linear correlation coefficient of 8 heavy metals is not less than 0. 999 3. The limits of detection( LODs) is between 0. 003- 0. 06 μg / L,standard addition recovery rate is between 95. 6%- 104. 9%. The relative standard deviations( RSD) is between 0. 53%- 1. 84%. [Conclusion] The method is simple,accurate and highly sensitive for the determination of 8 heavy metals in vegetables.

About this research paper

What this paper is about

[Objective]A method for determination of heavy metals in vegetables by inductively coupled plasma mass spectrometry( ICP-MS)is proposed. [Method] The samples were digested by a mixed reagent of HNO3- H2O2 sealed vessels. Rh and Re were selected as internal standard to compensate the analytical signal drift. The method was verified by national standard substance elements. [Result] It is shown that the linear correlation coefficient of 8 heavy metals is not less than 0. 999 3. The limits of detection( LODs) is between 0. 003- 0. 06 μg / L,standard addition recovery rate is between 95. 6%- 104. 9%. The relative standard deviations( RSD) is between 0. 53%- 1. 84%. [Conclusion] The method is simple,accurate and highly sensitive for the determination of 8 heavy metals in vegetables.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

[Objective]A method for determination of heavy metals in vegetables by inductively coupled plasma mass spectrometry( ICP-MS)is proposed. [Method] The samples were digested by a mixed reagent of HNO3- H2O2 sealed vessels. Rh and Re were selected as internal standard to compensate the analytical signal drift. The method was verified by national standard substance elements. [Result] It is shown that the linear correlation coefficient of 8 heavy metals is not less than 0. 999 3. The limits of detection( LODs) is between 0. 003- 0. 06 μg / L,standard addition recovery rate is between 95. 6%- 104. 9%. The relative standard deviations( RSD) is between 0. 53%- 1. 84%. [Conclusion] The method is simple,accurate and highly sensitive for the determination of 8 heavy metals in vegetables.

Key concepts: Inductively coupled plasma mass spectrometry, Chemistry, Reagent, Mass spectrometry, Detection limit, Recovery rate, Inductively coupled plasma, National standard

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of 8 Heavy Metals in Vegetables by Inductively Coupled Plasma Mass Spectrometry — Research Paper | ScholarLens