2010Chinese Journal of Analysis LaboratoryRequires access

Determination of Al、Mn、Ni、Zn、Pb、Th in rare earth chloride and carbonate by inductively coupled plasma-mass spectrometry

Deng Dong-qing

Open publisher page 0 citations

Abstract

A method for the determination of impurities( Al、Mn、Ni、Zn、Pb、Th)in rare earth chloride and carbonate by inductively coupled plasma-mass spectrometry is described.The acidity of sample solution,spectroscopic interference and matrix effect of the ICP MS method were investigated in detail.The rare earth matrix suppression effect and sensitivity drift can be effectively compensated by adopting indium as internal standard.The RSDs were in the range of 0.70%~2.44%,respectively.The recoveries were in the range of 98%~103%.

About this research paper

What this paper is about

A method for the determination of impurities( Al、Mn、Ni、Zn、Pb、Th)in rare earth chloride and carbonate by inductively coupled plasma-mass spectrometry is described.The acidity of sample solution,spectroscopic interference and matrix effect of the ICP MS method were investigated in detail.The rare earth matrix suppression effect and sensitivity drift can be effectively compensated by adopting indium as internal standard.The RSDs were in the range of 0.70%~2.44%,respectively.The recoveries were in the range of 98%~103%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for the determination of impurities( Al、Mn、Ni、Zn、Pb、Th)in rare earth chloride and carbonate by inductively coupled plasma-mass spectrometry is described.The acidity of sample solution,spectroscopic interference and matrix effect of the ICP MS method were investigated in detail.The rare earth matrix suppression effect and sensitivity drift can be effectively compensated by adopting indium as internal standard.The RSDs were in the range of 0.70%~2.44%,respectively.The recoveries were in the range of 98%~103%.

Key concepts: Chemistry, Inductively coupled plasma mass spectrometry, Chloride, Carbonate, Inductively coupled plasma, Matrix (chemical analysis), Mass spectrometry, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Al、Mn、Ni、Zn、Pb、Th in rare earth chloride and carbonate by inductively coupled plasma-mass spectrometry — Research Paper | ScholarLens